User Manual
RONDA
®
2600 The Vac for Factories and Warehouses
23
V. BRØNDUM A/S
Trouble Shooting
If the appliance does not collect the material in a satisfactory way:
The suction hose, tube or nozzle may be blocked.
Stop the appliance and remove the blocking.
The collection container may be filled to overflowing.
Stop the appliance and empty the container. See the section “Emptying”.
There might have been a leak during the assembly of the motor top.
Start the appliance, and block the suction hose. You will normally be able to hear a possible leak. Loosen
the container clips of the motor top, remount the motor top, and lock the container clips again.
The multi-tube filter may be blocked.
Clean the multi-tube filter as described in the section ”Filter Cleaning during Operation”.
The HEPA-filter may be blocked.
Replace the filter as described in the section ”Replacing the Filters”.