Level limit switch
Series VN 1000 / 2000 / 5000 / 6000
Technical information / Instruction manual
page
Remove and reassemble of the connection cable
Assembly: VN ..020 / ..030 with separate d- or de- housing
Oscillating
piece
inner
shield
black
red
white
Connection
cable
Cable gland
Connection
cable
Plug
Tube
Mating
plug
Threaded
bush
Fixing
screws
The units with separate housing are factory delivered completely
assembled.
Should it be required to remove the connection cable from the
housing due to shortening the cable or leading the cable through
a pipe or wall, observe following items.
Before planning to shorten the cable, check if it is possible to
loop the cable between housing and oscillationg piece (prefered
solution).
Remove the cable only on the housing side, never on
the oscillating piece side.
For reassembling observe following items:
• After cutting the cable, use the factory provided cable situation
as a sample.
• Connect the outer shield of the connection cable to the cable
gland.
• Obtain right connecting sequence on the plug (see drawing).
• Cut present cables, which are not required.
• Isolate the inner shield with an isolation hose to avoid that it
may touch any other metal parts.
• Connect plug and mating plug.
• Screw the tube into the threaded bush.
Before screwing check that Inside the threaded bush a seal ring
is present which seals the tube to the threaded bush.
While screwing, the cable gland must be open to avoid, that the
connection cable is beeing twisted. Take care, that the plug is
not removing from the mating plug.
• Fasten the two fixing screws.
The cable gland cable must be closed tightly to reach
ingress protection IP67 or NEMA 4.
min. bending radius of the
cable : 50mm (2")
Vibranivo
®
1
2
3
4
5
6
7
8
9
10
11
12
VN 1000 / 2000 / 5000 / 6000 g
gi180713
39