background image

c.

 

UNIT WEIGHT

 window shows 

Add

.

 XX

, for 

XX

 is the number of transactions saved in memory, 

while the 

TOTAL COUNT

 window will show the accumulated result with 

TOTAL

 indicator on. 

Both information will remain on display for 1 second and return to normal weighing   

d.

 

M+ 

indicator is switched on meaning there are data saved in memory 

e.

 

Remove item from platter and repeat the above steps to save the next transaction   

 

5.4.2 To Recall From Memory 

a.

 

Press 

MR

 once to recall the total amount of transactions saved in memory, 

WEIGHT

 window 

shows the total accumulated weight,

 UNIT WEIGHT 

window shows 

tot. XX

, for 

XX

 is the 

number of transactions saved in memory, while the 

TOTAL COUNT

 window will show the 

accumulated quantity with 

TOTAL

 indicator on 

b.

 

Information on display will show for 3 second and return to normal weighing   

 

5.4.3 To Delete From Memory 

a.

 

Press 

MR

 to recall the accumulated data from memory 

b.

 

Press 

CL

 after 

MR

 is pressed   

c.

 

Memory is cleared and 

M+

 indicator is off   

d.

 

If any other key instead of 

CL

 is pressed after pressing 

MR

, memory will not be deleted   

 

5.5

 

HOW TO USE CHECK FUNCTION   

The check function provides an audible warning towards the upper limit set by user for either total 

quantity or gross weight 

a.

 

Press 

CHK

 and display will show 

CHECK

 on 

TOTAL COUNT

 window   

b.

 

Use numeric keypad to enter either the upper limit for quantity or weight 

c.

 

If the value entered is for total quantity, press 

QTY SET

; if the value entered is for weight, press 

WT. SET

 

d.

 

If the value entered is incorrect, press 

CL

 to clear the value. If the intend function is wrongly 

pressed, restart the check function 

e.

 

To cancel the check function, press 

CHK

 first and press digit key 

0

. When the value 0 is flashing 

in the 

UNIT WEIGHT

 window, press either 

QTY SET

 or 

WT. SET 

to cancel the function which was 

previously engaged 

 

5.6

 

AUTO PIECE WEIGHT ENHANCEMENT FUNCTION 

This scale equips with auto piece weight enhancement function, which activates automatically 

when the piece weighing is obtained through 

5.3.1 Automatic Sampling

. This function provides a 

constant monitoring on the changes on the unit piece weight to obtain the most precise counting 

result. The updated unit piece weight will show on the 

UNIT WEIGHT

 window follows by a short 

beep. 

Summary of Contents for VOC Series

Page 1: ......

Page 2: ...ABLE OF CONTENT 1 BEFORE USE FOR THE FIRST TIME 2 INTRODUCTION 3 PANEL AND KEYBOARD 4 INTERNAL FUNCTIONS 5 INSTRUCTION TO USE 6 DAILY CARE AND MAINTENANCE APPENDIX ERROR CODES DISPLAY SEGMENT DEFINATION ...

Page 3: ...ensure the best battery performance Always use factory supplied power adaptor for charging purpose an unapproved power adaptor may shorten the battery life and further damages the electronic components Warm up the scale for 15 minutes before use for the first time Make sure the capacity and division setup on the display when switching on is the same as the data plate Avoid to use the scale when th...

Page 4: ...2g 15kg 6kg 15kg 2g 5g 30kg 15kg 30kg 5g 10g 6000 DIVISIONS Model No Capacity Max Readability e 3000g 3000g 0 5g 6000g 6000g 1g 12kg 12kg 2g 30kg 30kg 5g LCD Digits VGC Weight Unit Weight 5 digits Total Count 6 digits VOC Weight Unit Weight Total Count 6 digits Power on Zero Range 10 of Max Zero Range 2 of Max Tare Range Full Range Tare Platter Size 230 x 245mm with Stainless Steel Cover Power Sou...

Page 5: ...ng result is below true zero 3 NET INDICATOR It appears when tare function is engaged and weight shown is the net weight 4 PRESET TARE INDICATOR It appears when a preset tare is engaged 5 W1 INDICATOR This indicates the scale is set with dual range and the weight is within the first range Max1 e1 6 W2 INDICATOR This indicates the scale is set with dual range and the weight is within the second ran...

Page 6: ...g to prolong the time of rechargeable battery 10 LOW UNIT WEIGHT INDICATOR This indicator appears when the fix unit price function is engaged meaning the unit price enter can only be cancelled manually 11 LOW SAMPLE SIZE INDICATOR This indicator appears when pay change function is engaged and as a reminder for user to enter the amount receives from customer 12 CHARGING STATUS Red light indicates A...

Page 7: ...his key to preset tare CL Press this key to clear the unit price entered wrongly or to escape and returning to weighing mode M Press this key to save the weighing result to memory MR Press this key to recall the total accumulated weighing results from memory WT SET Press this key to manually enter the unit piece weight Q TY SET Press this key to enter the number of piece of the load CHK Press this...

Page 8: ...justing backlight brightness Open F 3 Scale configuration setup Dealer only when LOCKED F 4 Auto power off Dealer only when LOCKED F 5 Transmission protocol for RS 232 RS 485 Open F 6 1 Digital motion filter 2 Animal weighing Open F 7 transmission mode data format for RS 232 RS 485 Open F 9 Auto tare Open F 16 Turning on off real time clock Open F 17 Time and date setup Open F 18 Buzzer sound Open...

Page 9: ... the changes made or press CL for not to save the changes CAUTION BEFORE LEAVING THE INTERNAL SETTING ALL CHANGES MUST BE SAVED OTHERWISE THE SCALE WILL STILL FUNCTION UNDER THE OLD SETTING 4 1 2 Offset Value Function Key Test Under this function scale will show the offset value and be able to check the function of each key a Scale is off b Press and hold TARE and press ON OFF display shows F 1 c ...

Page 10: ...display will show SAVE user can either press ZERO for yes to save the changes made or press CL for not to save the changes 4 1 5 Backlight Timing Under this function user can select when to turn off backlight a Scale is off b Press and hold TARE and press ON OFF display shows F1 c Continue pressing TARE until display shows F38 d Press ZERO to enter and display shows bL 10 e Press MR to select the ...

Page 11: ...essed display will show SAVE user can either press ZERO for yes to save the changes made or press CL for not to save the changes 4 1 8 Transmission Protocol Under this function user can select the transmission interface speed mode and format for RS 232 and also the communication protocol a Scale is off b Press and hold TARE and press ON OFF display shows F1 c Continue pressing TARE until display s...

Page 12: ...y to confirm i Press MODE to confirm and exit the current function display shows F8 j Press MODE to enter the next function or press ZERO to exit When ZERO is pressed display will show SAVE user can either press MODE for yes to save the changes made or press ZERO for not to save the changes Terminology trAnS transmission mode ForMt result format Sample of print data StrM continue sending data when...

Page 13: ...oes not support print total 10 05kg 10 05kg 6 00kg 0 00kg When format setting is Ser 2 data is sent once when weighing result stables and print total value when pressing MC S N WT U W QTY 1 64 3 0 53589 120 print single date when result stables 2 137 7 0 53592 257 3 168 8 0 53590 315 4 101 3 0 53591 189 5 100 M manually enter the quantity without weighing Sum 472 1g 981pcs print total result when ...

Page 14: ... 53592 257 3 168 8 0 53590 315 4 101 3 0 53591 189 5 100 M manually enter the quantity without weighing Sum 472 1g 981pcs print total result when pressing MC 4 1 10 Time and Date Setup Use this function to setup year month and date as well as time in 24 hours format a Scale is off b Press and hold TARE and press ON OFF display shows F1 c Continue pressing TARE until display shows F17 d Press ZERO ...

Page 15: ...h Press M to exit display will show SAVE user can either press ZERO for yes to save the changes made or press CL for not to save the changes ...

Page 16: ... the item from platter and put on the next item Use the numeric keypad to enter the unit weight and total piece count will be shown in the TOTAL COUNT window 5 2 HOW TO USE TARE FUNCTION This scale equips with auto tare function please refer to F9 of internal setting auto continuous tare manual tare and preset tare a If auto tare function is enabled weight will be automatically tared off the initi...

Page 17: ...he result of calculation from weight being placed on the platter against with unit piece weight There are two methods to obtain the unit weight 5 3 1 Automatic Sampling a Refer to the above steps about how to weigh and place a known quantity on platter b Use numeric keypad to enter the known quantity and press QTY SET c Scale will show the piece weight in UNIT WEIGHT window 5 3 2 Direct Entry a Re...

Page 18: ...ed after pressing MR memory will not be deleted 5 5 HOW TO USE CHECK FUNCTION The check function provides an audible warning towards the upper limit set by user for either total quantity or gross weight a Press CHK and display will show CHECK on TOTAL COUNT window b Use numeric keypad to enter either the upper limit for quantity or weight c If the value entered is for total quantity press QTY SET ...

Page 19: ...x unit weight 2 After the initial sampling the next load place on the platter must not exceeds 100 of the original count 5 7 HOW TO CONNECT RS 232 D sub 9 pin female connector a Refer to 4 1 8 to set the transmission protocol b Data code ASCII Pin Assignment PC end Pin Assignment 1 DCD 2 RXD 3 TXD 4 DTR 5 GND 6 DSR 7 RTS 8 CTS 9 NC PC end Scale end 2 2 3 3 5 5 Only need to connect Pin2 3 and 5 ...

Page 20: ... to avoid permanent damage to the rechargeable battery Do not put anything on the platter after weighing completes to avoid causing damage to the load cell If cleaning is needed use damp cloth to clean the scale body Stainless steel platter can be removed for cleaning purpose If cleaning agent is needed please use mild detergent and avoid excessive water Do not use any chemical or alcohol for clea...

Page 21: ...contact dealer for assistance Err 1 A D accessing error Check A D contact dealer for assistance No load cell signal load cell reading error Check load cell and connection Err 2 Load cell wiring error Check load cell wiring pin assignment Err 3 Offset value too low too high DISPLAY SEGMENT DEFINATION ...

Reviews: