background image

Dynamics

UVD320E 

Installation and Maintenance Manual 

READ AND UNDERSTAND ALL 

INSTRUCTIONS BEFORE INSTALLING OR 

USING THIS PRODUCT 

PERFORMANCE 

CONSIDERATIONS 

The performance of the UVD320E UV disinfection chamber has been 

third party validated using accepted bio-assay techniques. The 

UVD320E is equipped with both visible and audio lamp failure alarms. 

For your safety, it is necessary that you determine that the audio 

alarm can be heard where you use the water treated by the unit. It is 

possible to operate the unit with the lamp disconnected which will 

allow you to validate the adequacy of the audio alarm function in your 

installation. In order to optimize disinfection performance, you must 

only use the unit with water that meets the minimum standard and 

replace the UV lamp at recommended intervals. Failure to follow these 

guidelines will result in reduced disinfection performance. 

UV RADIATION HAZARD 

NEVER OPERATE UV LAMP OUTSIDE OF THE UV 

DISINFECTION CHAMBER - EXPOSURE TO UV LIGHT 

CAN RESULT IN EXTREME BURNING OF SKIN AND EYES 

Safety instructions - Please read carefully 

Danger: 

Do not plug the unit in if any of the external 

surfaces or electrical parts are wet. Condensation on 

the disinfection chamber is normal. 

Danger: 

To avoid possible electric shock, special care should be 

taken since water may be present near electrical equipment.  Unless 

referred to in these instructions, do not attempt repairs yourself. 

Contact the manufacturer for service advice. 

Danger: 

Do not operate this system if it has a damaged electrical cord 

or plug, is malfunctioning, or has been dropped or damaged in any 

way. 

Caution: 

Do not use this unit for anything other than its intended 

potable water application.  The use of attachments not recommended, 

approved or sold by the manufacturer/distributor may result in an 

unsafe condition. 

Caution: 

Before any cleaning or maintenance, always unplug the unit. 

Caution: 

Protect your unit from freezing.  Drain all water from the unit 

if freezing temperatures exist. 

Caution: 

To prevent damage to the power source the use of a surge 

protector is recommended in areas with frequent power outages. 

WATER QUALITY 

Your UV disinfection system requires clean water for optimum 

performance.  You should only operate your unit if the source water 

meets the following standards. 

Turbidity 

Suspended Solids 

Colour 

Total Iron 

Manganese 

Hardness 

< 1 NTU 

< 10mg/L 

None 

< 0.3 mg/L 

< 0.06 mg/L 

< 7 gpg 

INSTALLATION CAUTIONS 

Oconnect 

your UV unit to a grounded (3 pronged) receptacle (120V, 

60HZ) 

(a GFI is highly recommended) 

and ensure that the lamp 

connector ground wire is connected to the ground stud on the top of 

the reactor vessel. Note: Power source for applications outside of 

North America must match requirements of the unit (eg. 240V, 50Hz). 

8uv 

Dynamics disinfection devices are designed to be installed on 

the cold water line only. 

@The unit must be 

installed vertically 

with the lamp connector 

pointing upwards -the water source should only be connected to the 

inlet port on the bottom of the unit. 

CAUTION: 

reversing the flow 

direction by connecting the water source to the side mounted output 

port could result in reduced disinfection performance. 

81nstall 

your UV Dynamics disinfection system indoors in a protected 

area where the temperature does not fall below 4

°

C. (40

°

F) and the 

humidity level is low (to prevent condensation on the chamber).  This 

unit functions ideally in a temperature range from 9

°

C - 29

°

C. (49 -

85F) 

0use 

teflon tape on all pipe connections. 

DO NOT USE ANY 

OTHER SEALANT. 

0 If the installation location is subject to frequent power outages, 

surges, brown out conditions or electrical storm activity, a surge 

protection device should be installed on the AC supply to prevent 

damage to the power source. 

8 Do not connect UVDynamics disinfection systems directly to PEX 

tubing or other plastic piping. Plastic material will suffer structural 

degradation, and possible service failures, when subjected to long­

term UV light exposure. PEX tubing and plastic piping can be 

connected directly to the inlet port 

if it is located on the bottom of 

the chamber. 

All side ports will require the use of a metallic light dam 

(16"/40cm section of metallic tubing, street elbow or stainless steel 

flex connector suitably bent to prevent direct UV radiation) 

MOUNTING BRACKET 

SUGGESTED INSTALLATION 

LAMP CONNECTOR 

lN POWER SOURCE 

MOUNTING SURFACE 

UV POWER SOURCE 

MOUNTING DETAIL 

MOUNTING SURFACE 

PLASTIC BRACKET 

,,. 

WORMGEAR CLAMP 

UV CHAMBER 

DIRECTION OF FLOW 

,, 

UV REACTOR CHAMBER 

MOUNTING DETAIL 

UV Dynamics  Inc 

www 

uvclynam,cs com 

315  Neptune Crescent. 

London.  Ontario  N6M  1A9 

phone 800 667 4629  fax 519 452 1701 

© COPYRIGHT 2011 • UVDynamics Inc. • All RIGHTS RESERVED 