SVD48V Series hub motor servo controller user manual
35
6.4 Confirm board information
In the functional area, select board parameters, configure CAN/RS485 communication address ID,
and configure RS485 and CAN baud rates respectively. Set the overvoltage protection voltage,
and control interface type.
6.5 Confirm the general parameters of the motor
General parameters of the motor, check whether the information of the motor and encoder is correct.
Here you can use the parameter import function to import
We provide factory parameter configuration files. It is also possible to import profiles that the user
has previously exported. The parameters imported into the configuration file will be updated to the
setting value list, but they are not delivered and saved to the drive. After modifying the setting values,
you can directly save the parameters to the drive through the " Write Parameters " button .
6.5.1
General Motor Parameters
Motor Maximum RPM
: Modified according to the maximum speed of the selected motor and the
maximum speed required by the user. The given speed is not allowed to be greater than the
maximum speed of the motor.
maximum current of the motor
: This refers to the maximum current that the driver can drive the
motor, which generally corresponds to the maximum peak current of the motor.
The greater the flow, the greater the motor peak torque. The maximum current that can be set cannot
exceed the maximum current specified by the drive model.