Technical Data of CryptoServer LAN V4 (AC Power Supply)
Page 40 of 42
7
Technical Data of CryptoServer LAN V4 (AC Power Supply)
Dimensions
Height
88 mm (2 slots (height units))
Width
446 mm without attachment bracket (19″)
Depth
472 mm excluding handles
Weight
13 kg
Operating power
100 V ~240 V, 50~60 Hz AC
Power supply
2 x 320 W
Power consumption
(effective/apparent)
Typically 75 W/85 VA, maximum 90 W/100 VA
Heat dissipation
307 BTU/h
Environmental
temperature
in operation CryptoServer Se-Series Gen2: +10 °C to +50 °C
CryptoServer CSe-Series: +10 °C to +40 °C
in storage
-10 °C to +55 °C (+14 °F to +131 °F)
Humidity
10% to 95% relative humidity, non-condensing
MTBF
90 000 hours at 25 °C/77 °F (in acc. with MIL-HDBK-217)
RoHS compliance
Yes
WEEE
National register for waste electric equipment (EAR) DE39805015
Conformity
EMC emission: CISPR 22 / CISPR 32 Class B, IEC/EN 61000-3-2,
IEC/EN 61000-3-3
EMC immunity: EN 300386, EN 55024 / CISPR 24, IEC/EN 61000-6-2
Equipment safety: IEC/EN 60950-1 (CB scheme)
FCC 47 CFR Part 15 Class B
UL
Climatic and mechanical conditions: EN 300 019: Storage class 1.1,
Transportation class 2.1 (with temperature range restricted to the storage
environmental temperature given above), stationary use in environments that
are protected from the weather class 3.1