background image

 

Questions, problems, missing parts? 

Before returning to the store, call our customer  

service department at 1-866-994-4148, 8 a.m. - 8 p.m., EST, Monday - Sunday. You could 

also contact us at [email protected]

ITEM # 4984545

3-IN-1 DECORATIVE 

VENTILATION FAN WITH 

LED LIGHT

MODEL 7105-08-L

Español p. 13

READ AND SAVE THESE INSTRUCTIONS

01/2022

ATTACH YOUR RECEIPT HERE

Serial Number ___________________________ Purchase Date  __________________________

UTILITECH & logo design are trademarks or registered 

trademarks of LF, LLC. All rights reserved.

AS22001

Summary of Contents for 4984545

Page 1: ...ct us at partsplus lowes com ITEM 4984545 3 IN 1 DECORATIVE VENTILATION FAN WITH LED LIGHT MODEL 7105 08 L Español p 13 READ AND SAVE THESE INSTRUCTIONS 01 2022 ATTACH YOUR RECEIPT HERE Serial Number____________________________ Purchase Date ___________________________ UTILITECH logo design are trademarks or registered trademarks of LF LLC All rights reserved AS22001 ...

Page 2: ... consumption 15 Watts 120 V 60 Hz LED life 30 000 hours Duct diameter 4 in LED light brightness 1000 lumens dimmable Motor power consumption 28W Product Specifications 2 Package Contents 2 Hardware Included 2 Safety Information 3 Preparation 3 New Construction Installation Instructions 5 Existing Construction Installation Instructions 7 Care and Cleaning 11 Troubleshooting 12 Warranty 12 HARDWARE ...

Page 3: ...s to be installed over a tub or shower it must be marked as appropriate for the application and be connected to a GFCI Ground Fault Circuit Interruptor protected branch circuit 8 This ventilation fan is intended to be installed at least 3 ft 3 1 4 in 1 m from the showerhead when installing over a bathtub or shower Installation within a shower stall is not recommended for this unit unless the 3 ft ...

Page 4: ...maller Do not reuse the connector on stranded wires Strip wires 3 8 in 1 2 in Grip the wire firmly and push the stripped end of the wire into the open port of the connector Use only one conductor per port Verify the stripped end of the wires is fully inserted to the back of the connector CAUTION Wiring maximum temperature rating 221 F 105 C 600V maximum for building wiring and 1 000V maximum for s...

Page 5: ...tor C flap A C 1 2 Place the fan housing A next to a ceiling joist The fan housing A should be level and perpendicular to the joist Allow for thickness of ceiling board used in your application Position the fan housing A so the bottom edge of the fan housing A is flush with the ceiling board Do not flush mount the fan housing A to the bottom of the joist A 2 3 Mount the fan housing A to the joist ...

Page 6: ...ing box housing and reattach the wiring box cover CAUTION If your electrical wires do not match the colors listed consult a licensed electrician to determine what each house wire represents before connecting the fan Quick connector Wiring box cover Wiring box cover 5 6 Connect a 4 in circular duct to the duct connector on the fan housing A securing it with duct tape or a clamp Vent the duct to the...

Page 7: ...nt Place an alternate grille trim piece D around the grille with LED light B until the magnetic attachment is secure 9 Alternate trim finish B D EXISTING CONSTRUCTION INSTALLATION INSTRUCTIONS BEFORE INSTALLATION WARNING RISK OF ELECTRIC SHOCK Ensure the electricity to the wires you are working on is shut off Either remove the fuse or turn off the circuit breaker before removing the existing bath ...

Page 8: ... the duct connector C to the fan housing A NOTE Remove the protective tape on the duct connector C flap A C 4 5 Remove the three screws on the side of the fan housing A that hold the fan motor in place With the screws removed unplug the fan motor and pull the fan motor out of the fan housing A A Fan motor plug Fan motor 5 6 Remove the wiring box cover from the fan housing A 6 Wiring box cover A ...

Page 9: ...determine what each house wire represents before connecting the fan Quick connector Wiring box cover Wiring box cover 7 8 Connect a 4 in circular duct to the duct connector on the fan housing A securing it with duct tape or a clamp Vent the duct to the outside 4 in duct A Ceiling Duct tape or clamp 8 9 With the wiring and duct connected insert the fan housing A into the ceiling hole Position the f...

Page 10: ...ousing A to the grille B The grille B must be connected before turning on power to the fan 2 hole 4 hole A B 12 13 Attach the grille B by pinching the mounting springs and inserting them into the narrow rectangular slots in the fan housing A Turn on power source Test the unit 13 Housing slots Mounting springs A B 14 If desired the trim finish can be changed To change the trim pull down gently from...

Page 11: ...ING RISK OF ELECTRIC SHOCK Ensure the electricity to the wires you are working on is shut off Either remove the fuse or turn off the circuit breaker before cleaning 1 Remove the grille B by squeezing the mounting springs and pulling the grille B down from the fan housing A Disconnect the connectors to remove the grille B from the fan housing A Wipe grille B with a damp cloth 1 A B 2 Remove dust an...

Page 12: ...cted to 1 866 994 4148 8 a m 8 p m EST Monday Sunday You could also contact us at partsplus lowes com TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION The fan seems louder than it should be The CFM is too great Be sure the CFM rating on the fan matches the square footage of your room The damper is damaged or not working properly Check the damper to ensure it is opening and closing properly If the d...

Page 13: ...el Este También puede contactarnos en partsplus lowes com LEA Y GUARDE ESTAS INSTRUCCIONES ADJUNTE SU RECIBO AQUÍ Número de serie__________________________ Fecha de compra _________________________ UTILITECH y el diseño del logotipo son marcas comerciales o marcas registradas de LF LLC Todos los derechos reservados ARTÍCULO 4984545 VENTILADOR DECORATIVO 3 EN 1 CON LUZ LED MODELO 7105 08 L ...

Page 14: ...o 4 pulg Brillo del LED 1000 lumenes regulable Consumo eléctrico del ventilador 28 vatios Especificaciones del producto 14 Contenido del paquete 14 Materiales incluidos 14 Información de seguridad 15 Preparación 15 Instrucciones de installación de nueva construcción 17 Instrucciones de installación de construcción existentes 19 Cuidado y limpieza 23 Solución de problemas 24 Garantía 24 PARTE DESCR...

Page 15: ...ón protegido GFCI Interruptor de circuito de falla a tierra 8 Este ventilador está diseñado para instalarse por lo menos a 1 m del cabezal de la ducha cuando se instala sobre una bañera o ducha La instalación dentro de una cabina de ducha no se recomienda a menos que se pueda alcanzar la distancia de 1 m PRECAUCIÓN Para uso de ventilación general solamente No lo use para desalojar materiales y vap...

Page 16: ... posterior del conector PRECAUCIÓN temperatura máxima del cableado 105 C 221 F Máximo 600 V para cableado de edificios y 1 000 V máximo para letreros y lámparas El rango de cable aceptable es 12 18 AWG cobre sólido Se recomienda aplicar un aislamiento adecuado alrededor del ventilador para minimizar la pérdida y ganancia de calor Este ventilador está diseñado para instalarse con un conducto de 4 p...

Page 17: ...l ventilador A al lado de una viga del techo La carcasa del ventilador A debe estar nivelada y perpendicular a la viga Permita el grosor de la placa de techo utilizada en su aplicación Coloque la carcasa del ventilador A de modo que el borde inferior de la carcasa del ventilador A quede al ras con la placa del techo No monte la carcasa del ventilador A al ras de la parte inferior de la viga A 2 3 ...

Page 18: ...ado y vuelva a colocar la tapa de la caja de cableado PRECAUCIÓN si sus cables eléctricos no coinciden con los colores enumerados consulte a un electricista con licencia para determinar qué representa cada cable de la casa antes de conectar el ventilador Conector rápido Tapa de la caja eléctrica Tapa de la caja eléctrica 5 6 Conecte un conducto circular de 4 pulg al conector del conducto en la car...

Page 19: ... un reborde de rejilla alternativo D alrededor de la rejilla con luz LED B hasta que la fijación magnética quede asegurada 9 B D Reborde para rejilla alternativo INSTRUCCIONES DE INSTALACIÓN DE CONSTRUCCIÓN EXISTENTE PREVIO A LA INSTALACIÓN ADVERTENCIA RIESGO DE DESCARGA ELÉCTRICA Asegúrese de cortar el suministro eléctrico en los cables con los que trabajará Extraiga los fusibles o apague el cort...

Page 20: ...r A NOTA retire la cinta protectora de la aleta del conector del conducto C A C 4 5 Retire los tres tornillos en el lado de la carcasa del ventilador A que sujetan el motor del ventilador en su lugar Con los tornillos retirados desenchufe el motor del ventilador y extraiga el motor del ventilador de la carcasa del ventilador A A Enchufe del motor del ventilador Motor del ventilador 5 6 Retire la c...

Page 21: ...a casa antes de conectar el ventilador Conector rápido Tapa de la caja eléctrica Tapa de la caja eléctrica 7 8 Conecte un conducto circular de 4 pulg al conector del conducto en la carcasa del ventilador A asegurándolo con cinta adhesiva o una abrazadera Ventile el conducto hacia el exterior Conducto de 4 pulg A Techo Cinta adhesiva o abrazadera 8 9 Con el cableado y el conducto conectados inserte...

Page 22: ...r A a la rejilla B La rejilla B debe estar conectada antes de encender el ventilador 2 agujeros 4 agujeros A B 12 13 Fije la rejilla B apretando los resortes de montaje e inser tándolos en las ranuras rectangulares estrechas en la carcasa del ventilador A Encienda la fuente de alimentación Pruebe el ventilador 13 A B Resortes de montaje Ranuras en la caja 14 Si así lo desea se puede cambiar el aca...

Page 23: ...ástico en agua a más de 60 ºC 140 ºF ANTES DE LIMPIAR ADVERTENCIA RIESGO DE DESCARGA ELÉCTRICA Asegúrese de que la energía esté apagada Quite el fusible o apague el disyuntor antes de limpiarlo 1 Retire la rejilla B apretando los resortes de montaje y tirando de la rejilla B hacia abajo desde la carcasa del ventilador A Limpie la rejilla B con un paño húmedo 1 A B 2 Use una aspiradora para elimina...

Page 24: ...ortes de montaje y se insertan en las ranuras rectangulares estrechas en la carcasa del ventilador A Encienda la fuente de alimentación 5 A B Resortes de montaje Ranuras en la caja Impreso en China GARANTÍA LIMITADA DE 5 AÑOS Si el ventilador falla debido a un defecto en el material o la mano de obra en cualquier momento durante los primeros CINCO años de poseerlo elfabricante lo reemplazará sin c...