![UTICA BOILERS MAC-115 Manual Download Page 8](http://html1.mh-extra.com/html/utica-boilers/mac-115/mac-115_manual_1065164008.webp)
4
Dimensions
PHYSICAL DATA
Central Heating (Sealed System)
100 / 115 / 125 / 150
/
165 / 205
Heat Exchanger Max Allowable Working Pressure
50 psi [3.45 bar]
Max System Pressure
43
psi
[2.96 bar]
Min System Pressure
7.25
psi [ 0.50 bar]
Max System temperature
176°F
[80°C]
Pressure Relief Valve Setting
30
psi [2.11 bar]
Expansion Tank Minimum Size
(pre-charge
press.)
(
100
/115)
1.5
gal at 11.6 psi
[7.0
L at
0.8 bar]
(125/150/165/205)
2.2
gal at 11.6 psi [10.0
L at
0.8 bar]
Recommended System Pressure (cold)
21.7 psi [1.5 bar]
Domestic Hot Water
115
150
205
Max Inlet Water Pressure
116 psi [8 bar]
Min Inlet Water Pressure
2.9 psi [ 0.2 bar]
Min DHW Flow Rate
0.55 gpm [2.50 L/min]
Max DHW Temperature
140°F [60°C]
DHW Water Content (Domestic Hot Water Flat Plate Content)
0.035 gal [0.13 L]
0.053 gal [0.23L]
0.10 gal [0.37 L]
SYSTEM
When boiler is operating at maximum operating temperature, providing heating with all heat emitters operating, pressure gauge
should not indicate more than 26.11 psi / 1.80 bar. If reading exceeds this figure larger expansion tank is required.
DIMENSIONS
100 / 125
115 / 150
165 / 205
Height
30" [763 mm]
Width
17
3/4
" [450 mm]
Depth
13
9/16
" [345 mm]
21
1/2"
[571 mm]
DIMENSIONS
Condensate Trap Connection
13/16"
[21 mm]
ID Hose
3/4" [19.1 mm]
NPT
System Supply
3/4” [19.1 mm]
1” [25.4 mm]
DHW Outlet (100 & 125 Optional)
3/4” [19.1 mm]
Copper Sweat
1/2” [15.9 mm]
Copper Sweat
165-NA
205 - 3/4” [19.1 mm]
Gas Connection
3/4” [19.1 mm]
DHW (Cold Water) Inlet
N/A
1/2” [15.9 mm]
Copper Sweat
165 - N/A
205 - 3/4” [19.1 mm]
Boiler Return
3/4” [19.1 mm] Copper Sweat
1” [25.4 mm]
Boiler Filling Connection
External to Boiler
Primary Water Content
0.95 gal [3.60 L]
1 gal [3.60 L]
1
1/4
gal [4.73 L]
B
B
I
H
G
F
E
C
A
240013354 REV B [09/15/2021]
A
C
Summary of Contents for MAC-115
Page 2: ...MAC 205 ...
Page 4: ...MAH 165 ...
Page 77: ...73 APPENDIX A WIRING DIAGRAMS A 2 MODEL 125 Heat Only 240013354 REV B 09 15 2021 ...
Page 78: ...74 APPENDIX A WIRING DIAGRAMS A 3 MODEL 165 Heat Only 240013354 REV B 09 15 2021 ...
Page 79: ...75 APPENDIX A WIRING DIAGRAMS A 1 MODEL 115 Combi 240013354 REV B 09 15 2021 ...
Page 80: ...76 APPENDIX A WIRING DIAGRAMS A 4 MODEL 150 Combi 240013354 REV B 09 15 2021 ...
Page 81: ...77 APPENDIX A WIRING DIAGRAMS A 5 MODEL 205 Combi 240013354 REV B 09 15 2021 ...
Page 82: ...78 NOTES 240013354 REV B 09 15 2021 ...
Page 118: ...34 MODEL 125 Heat Only 125 HEAT ONLY WIRING DIAGRAM PN 240011430 REV P 09 15 2021 ...
Page 119: ...35 MODEL 165 Heat Only 165 HEAT ONLY WIRING DIAGRAM PN 240011430 REV P 09 15 2021 ...
Page 120: ...36 115 COMBI WIRING DIAGRAM MODEL 115 Combi PN 240011430 REV P 09 15 2021 ...
Page 121: ...37 MODEL 150 Combi 150 COMBI WIRING DIAGRAM PN 240011430 REV P 09 15 2021 ...
Page 122: ...38 MODEL 205 Combi 205 COMBI WIRING DIAGRAM PN 240011430 REV P 09 15 2021 ...
Page 127: ...43 Low Water Cutoff Detail LOW WATER CUTOFF NO NO YES PN 240011430 REV P 09 15 2021 ...
Page 132: ...48 3 FAULT SOLUTION SECTIONS PN 240011430 REV P 09 15 2021 ...