15
ELECTRICAL WIRING
Install electrical wiring in accordance with requirements
of authority having jurisdiction, or in the absence of such
requirements, NFPA 70: National Electric Code.
A separate electrical circuit should be run from the entry
box with a fused disconnect switch in this circuit. See
wiring diagram
See
Figure 18 .
Wiring for zone valve installations are furnished with zone
valve packages.
Thermostat Installation
1.
Thermostat should be installed on an inside wall about
four feet above the floor.
2.
NEVER
install a thermostat on an outside wall.
3.
Do not install a thermostat where it will be affected
by drafts, hot or cold pipes, sunlight, lighting fixtures,
television, fireplaces, or chimneys.
4.
Check thermostat operation by raising and lowering
thermostat as required to start and stop the burner.
5.
Instructions for the final adjustment of the thermostat
are packaged with the thermostat (adjusting heating
anticipator, calibration, etc.).
WARNING
Electrical shock hazard. Turn OFF electrical power
supply at service panel before making electrical
connections. Failure to do so could result in death
or serious injury.
!