background image

12

2266 S

ECOND

 S

TREET

 N

ORTH

 

|

 

N

ORTH

 S

AINT

 P

AUL

 MN

 

|

 

800-777-2624

 

|

 

www.interlogixinc.com

©2002 GE Interlogix,™ Inc. GE Interlogix and LifeGard are trademarks of GE Interlogix, Inc.

Document Number: 466-1936 Rev. A

Summary of Contents for LifeGard

Page 1: ... PHUJHQF 5HVSRQVH 6 VWHP 8VHU QVWUXFWLRQV ...

Page 2: ... Pendant Panic 5 Setting up the System 7 Locating the Panel 7 Plugging in the Phone Line 7 Plugging in the Power 8 Powering up the System 8 Adjusting the Speaker Volume 8 Operation 9 Panic Operation 9 Remote Phone Control 10 Pager Communication 10 Testing the System 11 ...

Page 3: ... connected to a line as determined by the total RENs contact the local telephone company For products approved after July 23 2001 the REN for this product is part of the product identifier that has the format US AAAEQ TXXXX The digits represented by are the REN without a decimal point e g 03 is a REN of 0 3 For earlier products the REN is separately shown on the label If this equipment causes harm...

Page 4: ...a la satisfaction de l utilisateur Avant d installer ce matériel l utilisateur doit s assurer qu il est permis de le raccorder aux installations de l enterprise locale de télécommunica tion Le matériel doit également etre installé en suivant une méthod acceptée de raccordement Dans certains cas les fils intérieurs de l enterprise util isés pour un service individuel a ligne unique peuvent etre pro...

Page 5: ...open the buttons are used to program the emergency noti fication system The panel can be programmed on site by the installer or user Wrist Panic The Wrist Panic Sensor is a wireless device designed to be used throughout your premises The sensor is worn on the wrist with a wrist strap included Pendant Panic The Pendant Panic Sensor is a wireless device designed to be used throughout the installatio...

Page 6: ...6 Figure 1 Front of panel Figure 2 Back of panel Volume Power Status Call Button Speaker Volume Button Power LED Status Button Phone Jacks On Off Switch Menu Button ...

Page 7: ...cate the panel in a temperature and humidity controlled environment Plugging in the Phone Line There are two methods for connecting the panel to a phone line full line seizure and no line seizure Full Line Seizure This method requires that the panel be wired ahead or in front of all other phones answering machines computers or any other devices on the phone line This allows the panel to take over ...

Page 8: ...e sure the outlet is not controlled by a switch or that it is not part of a ground fault interrupt circuit GFIC Powering up the System Turn the Power switch on the back of the panel to On The panel voice should announce Hello system X is OK and the Power LED will light up Adjusting the Speaker Volume The Volume button on the front of the panel controls the volume of announcements from the speaker ...

Page 9: ...n is pressed and when the panel announces it is contacting the station Two Presses 1 Press the Call button once The panel announces Press call again for Emergency call or press Status to cancel 2 Press the Call button again to initiate an emergency call or press Status to cancel the call You may also initiate an emergency call by holding down the Call button until the system announces Contacting m...

Page 10: ...To connect to the LifeGard system 1 Call the panel location 2 Let the phone ring once then hang up 3 Wait at least 10 seconds but no more than 40 then call the panel location again The panel should answer on the first ring 4 Enter Master Access Code one of the following numbers 0 or 1 to talk through the panel 2 to have a 2 way conversation through the panel 3 or 6 to listen through the panel 99 t...

Page 11: ... sensors have been tested the panel will announce Sensor test com plete press Status 5 Press Status The panel says Sensor test OK Note The panel will prompt for each sensor in the order they were programmed If there are no sensors programmed the panel says Invalid Zero sensors programmed It is not necessary to test the sensors in the order they are announced by the panel Phone Test To test the pro...

Page 12: ...12 2266 SECOND STREET NORTH NORTH SAINT PAUL MN 800 777 2624 www interlogixinc com 2002 GE Interlogix Inc GE Interlogix and LifeGard are trademarks of GE Interlogix Inc Document Number 466 1936 Rev A ...

Reviews: