background image

UTC. All Rights Reserved. 

6

 

P/N 0000000 – Rev. A – 06 Nov 12  

15.

 

Regulatory Information 

Manufacturer: UTC Fire & Security  

 
WEEE Directive 

2002/96/EC (WEEE directive): Products marked with this symbol cannot 

be disposed of as unsorted municipal waste in the 
European Union. For proper recycling, return this product to 

your local supplier upon the purchase of equivalent new 
equipment, or dispose of it at designated collection points. 
For more information see: www.recyclethis.info.  

 

RoHs Directive

  

2002/95/EC RoHS Compliant. Hereby, UTC Fire & Security declares that 
this  product  does not contain lead, mercury, cadmium, hexavalent 
chromium, polybrominated biphenyls (PBB) or polybrominated 

depheny ethers (PBDE) in more than the percentage specified by EU 
directive 2002/95/EC, except exemptions stated in EU directive 
2002/95/EC annex. 
 

UL Rating

 

ANSI/UL 639 Recognized 
 

FCC Compliance 

 FCC ID:  QPY-5845GB-Z 
 

IC:  8303B-5845GB-Z 

 
The device complies with part 15 of the FCC Rules as well as Industry 
Canada Rules and Regulations license-exempt RSS standard(s). 
Operation is subject to the following two conditions: (1) This device may 

not cause harmful interference, and (2) this device  must accept any 
interference received, including interference that may cause undesired 
operation.  

 

Conformité Réglementaire 

Ce dispositif est conforme à la réglementation de la IC et (Partie 15) de 
la FCC. Son fonctionnement est soumis à deux conditions : (1) ce 
dispositif ne doit pas causer d’interférences nuisibles, et (2) ce dispositif 
doit accepter toute interférence reçue, y compris les interférences 

pouvant entraîner des conditions de fonctionnement indésirables. 
 

  WARNING: 

Changes to Section 15 –  Regulatory Information is 

strictly prohibited. Any changes or modification made  to the product 

without the permission of the manufacturer could void the user’s 
authority to use this product. 
 
 

16.

 

Product Information 

 

Disclaimer

 

This Glass Break Detector is not a complete alarm system, but only a 
part of. Therefore UTC Fire & Security does not accept any responsibility 

or liability for any damage that is claimed to be a result of an incorrect 
functioning of the Glass Break Detector. UTC Fire & Security reserves the 
right to change the specification without a prior notice. 
 

Limitations of Security Products 

 

Security products and alarm systems do not offer guaranteed 
protection against burglary, fire, or other emergencies. They may fail to 
warn for diverse reasons, including (but not limited to): power failure, 

dead batteries, improper installation, coverage, coverage areas 
overlooked during installation, defeat by technically sophisticated 
intruders, component failure, or inadequate maintenance. Alarm 
systems should be checked weekly to ensure that all devices are 

working properly.  

 

AN ALARM SYSTEM IS NOT A SUBSTITUTE FOR INSURANCE 

 

Limited Warranty 

Edwards is a brand of UTC Fire & Security. The manufacturer warrants 
this product (except batteries) to be free from defects in material and 

workmanship under conditions of normal use for a term of 3 years 
from the date of manufacture. 
 
During the warranty period, if a UTC Fire & Security product or any of its 

components becomes defective, it will be repaired or replaced without 
charge. 
 
Out-of-warranty units will be repaired at the discretion of the 

manufacturer or, if not, a card will be forwarded to the customer 
suggesting a replacement unit and the cost of that unit. 
 
This warranty does not apply to units which have been subject to 

abuse, 
misuse, negligence or accident, or to which any modifications, 
alterations or repairs have been made or attempted. 
 

This warranty is extended only to the original purchaser of the smoke 
alarm and may be enforced only by such person. During the warranty 
period, if the alarm or any warranted components thereof becomes 
defective, it will be replaced or repaired without charge at the 

manufacturer’s discretion if returned in accordance with the following 
instructions: 
 
Obtain a Return Authorization Number by calling the number below, 

then carefully pack it in a well padded and insulated carton and return, 
postal charges prepaid to: 
 
 
This product is manufactured by Edwards, a UTC Fire and Security 

Company, 8985 Town Center Parkway, Bradenton, FL 34202. 
 
Return units to: 

UTC – Climate, Controls & Security 

 

325 N Main St 

 

Pittsfield, ME 04967 

 

Phone: 1-207-487-3104 

 
A note should be included advising the nature of the malfunction. Care 
must be exercised in the proper packing of alarms returned under this 

warranty as UTC Fire &  Security will not be responsible for warranty 
repairs to equipment damaged because of improper packing. 
 
The above warranty is in lieu of all other express warranties, and 

implied  warranties of merchantability and fitness for a particular 
purpose are limited in duration for a period of THREE years from the 
date of manufacture. Under no circumstances shall manufacturer be 
liable to the purchaser or any other person for incidental or 

consequential damages of any nature, including without limitation 
damages for personal injury or damages to property, and however 
occasioned, whether alleged as resulting from breach of warranty by 
manufacturer, the negligence of manufacturer or otherwise. 

Manufacturer’s liability will in no event exceed the purchase price of the 
product. Some states do not allow limitations on how long an implied 
warranty lasts, or the exclusion or limitation of incidental or 
consequential damages, so the above limitations and exclusions may 

not apply to you. Unless a longer period is required by applicable law, 
any action against manufacturer in 
connection with this smoke alarm must be commenced within one 
year after the cause of action has occurred. 

 

Summary of Contents for 5845GBW-OEM

Page 1: ...e sensor is armed all day and all night The false alarm technology will be pushed to its limit in a 24 hour loop The sensor s false alarm immunity is best in rooms with only moderate noise Some sounds can duplicate the points on the glass break pattern the sensor detects The sensor may not consistently detect cracks in glass or bullets which break through the glass Glass break sensors should alway...

Page 2: ...ocated in the front Remove the top cover by using a flat bladed tool in the screw location to pry open the top cover Locate the mounting location and drill holes in base per the mounting impression in the base Use the anchors and screws to secure the product to the mounting surface C Replace the product s top cover Snap the top onto the base Replace the screw into the front location 4 Basic Operat...

Page 3: ...ntrol panel into sensor test mode for all testing helps to protect against false alarms and unintentional central station reporting This product has three test methods o Wake Up Test A hand clap should wake up the glass break detector o RF Communication Test Tests the communication path with the control panel o Glass Break Functional Test Tests the functional operation of the glass break sensing e...

Page 4: ...l 20 ft 6 m conditions Do not exceed the rated range of the sensor regardless of what the tester shows 8 Defaulting the Detector This step should only be performed by a qualified service technician A Remove the top cover from the product B Remove the battery C Press the enrollment switch in the RF circuit inside the product and hold until you replace the batteries D Replace the battery while still...

Page 5: ...trol panel The Sensor Diagnostic for Security Zone name appears as the system detects the current signal strength between the selected sensor and the control panel Trouble Refer to Section 13 for trouble shooting guidance Low Battery Replace the batteries per Section 5 Installing Replacing Battery 13 Troubleshooting Product does not power up properly or reports low battery o Be sure the battery is...

Page 6: ...king properly AN ALARM SYSTEM IS NOT A SUBSTITUTE FOR INSURANCE Limited Warranty Edwards is a brand of UTC Fire Security The manufacturer warrants this product except batteries to be free from defects in material and workmanship under conditions of normal use for a term of 3 years from the date of manufacture During the warranty period if a UTC Fire Security product or any of its components become...

Page 7: ...Manufacturer nor any other person is authorized to modify this warranty in any respect Repair or replacement as stated above is the exclusive remedy of the purchase hereunder This warranty gives you specific legal rights and you also have other rights which vary from state to state End of document ...

Reviews: