5
Local DGP databus programming
If the reader is connected to a 4-Door/Elevator Controller DGP local databus, do the following:
1. Disarm the system. In the normal operating
display (
), enter
1122
(default
manager code) and press
Off
. Enter
0
(select
all areas) and press
Enter
.
Figure 9. Normal operating display
2. Access the Alliance system menu. Press
Menu
, enter
1278
(default installer code),
and press
Enter
(
Access the installer programming. Enter
19
and press
Enter
.
Figure 10. Enter system menu display
3. Choose the
advanced
menu option. Press
Menu
(
).
To choose the
simple
menu option, press
Enter.
The simple menu option will limit
access to a number of options in installer
programming. We recommend that you
always choose the advanced menu option.
Figure 11. Simple/advanced menu display
4. Access Option 28 (remote devices). Enter
28
and press
Enter
. (
),
Figure 12. Installer programming display
5. Select DGP programming. Enter
1
and press
Enter
(
Figure 13. Remote devices display
6. Enter the address of the DGP to which the
reader is connected and press
Enter
. The
DGP number is the same as the DGP
address. (
Figure 14. DGP number display
7. Press
Enter
to display the first menu option
).
Figure 15. Menu selection display
00:00 01/01/2006
Code:
0-Exit ENTER-Down, *-Up
0-Exit, Menu:
Simple/Advanced Menu
*-Advanced
Installer Programming
0-Exit, Menu:
Remote Devices: 1-DGP, 2-RAS
Device:
Remote DGP Setup
DGP No:
#-Move On * Move Back
Menu