System databus programming
If the reader is connected to the system databus, do the following:
1. Disarm the system. In the normal operating
display (
), enter
1122
(default
manager code) and press
Off
. Enter
0
(select
all areas) and press
Enter
.
Figure 2. Normal operating display
2. Access the Alliance system menu. Press
Menu
, enter
1278
(default installer code),
and press
Enter
(
).
Access the installer programming. Enter
19
and press
Enter
.
Figure 3. Enter system menu display
3. Choose the
advanced
menu option. Press
Menu
(
).
To choose the
simple
menu option, press
Enter.
The simple menu option will limit
access to a number of options in installer
programming. We recommend that you
always choose the advanced menu option.
Figure 4. Simple/advanced menu display
4. Enter
3
and press
Enter
to access the RAS
database. Enter
16
(address of the RAS to
poll) and press
Enter
. Press
Clear
to exit
this menu.
Access Option 28 (remote devices). Enter
28
and press
Enter
. (
Figure 5. Installer programming display
5. Select RAS programming. Enter
2
and press
Enter
(
).
Figure 6. Remote devices display
6. Enter
16
(address of the RAS to program)
and press
Enter
. The RAS number is the
same as the RAS address. (
Figure 7. RAS number display
7. The resulting display is shown in
.
From this display you can program the
reader.
Figure 8. Menu selection display
00:00 01/01/2006
Code:
0-Exit ENTER-Down, *-Up
0-Exit, Menu:
Simple/Advanced Menu
*-Advanced
Installer Programming
0-Exit, Menu:
Remote Devices: 1-DGP, 2-RAS
Device:
Remote RAS Setup
RAS No:
Smart Reader AL-1191/AL-1193
0-Exit, Menu: