SU320CSX
4110-0446, Rev. B
Page 72 of 96
© 2016 UTC Aerospace Systems
Date Printed: 5-Dec-2016
This document does not contain any export controlled technical data.
5.17.9.
Get Focal Plane Array Number of Columns
Description
Returns the number of columns of the focal plane array.
Setting Type
Global
Command FPA:COLS?
Parameters none
Return Values
value
Range
0 to 65535
Type unsigned
integer
Example
FPA:COLS? -- query command
640 -- return value
5.17.10.
Get Focal Plane Array Number of Rows
Description
Returns the number of rows of the focal plane array.
Setting Type
Global
Command FPA:ROWS?
Parameters none
Return Values
value
Range
0 to 65535
Type unsigned
integer
Example
FPA:ROWS? -- query command
512 -- return value
5.17.11.
Get Elapsed Time Meter
Description
Returns the total amount of time the camera has been powered on
since production. User is unable to reset.
Setting Type
Global
Command ETM?
Parameters none
Return Values
value (Days Hours:Minutes:Seconds)
Range
0 - 2
32
seconds, or about 136 yrs
Type String
Example
ETM? -- query command
Days:8 04:03:02 -- return value