5.15.5.
Set Thermoelectric Cooler State
Description
Sets the state of the thermoelectric cooler.
Setting Type
Global
Command TEC:ENABLE
state
Parameters
state
Return Values
none
Range ON
Enables
TEC
OFF Disables
TEC
Type string
Example TEC:ENABLE
ON
5.15.6.
Get Thermoelectric Cooler State
Description
Returns the state of the thermoelectric cooler.
Setting Type
Global
Command TEC:ENABLE?
Parameters
state
Return Values
none
Range ON
TEC
Enabled
OFF TEC
Disabled
Type string
Example
TEC:ENABLE? -- query command
ON -- return value
5.15.7.
Wait for TEC Lock
Description
Blocks operation of camera until TEC is locked. Useful in cases
where passed data needs to be properly stabilized, such as in
performing an updated background correction file. Camera
operation is prevented for up to 60 seconds, and will unblock when
a stable TEC lock signal is achieved. Queries while blocked are not
received.
Setting Type
Global
Command TEC:WAIT
Parameters none