3NF-2
1-5-5
(2) Detaching and refitting the PF forwarding, PF paper feed and PF separation
pulleys (Right)
Procedure
1. Pull the cassette 3 completely.
2. Remove the four screws and then
remove the cassette 3.
Figure 1-5-7
3. Remove the hook and remove the for-
warding pulley (right) from the axle.
4. Remove the hook and remove the feed
pulley (right) from the axle.
Figure 1-5-8
Cassette 3
Screw
Screw
Screw
Screw
Hook
Paper feed
pulley
Forwarding
pulley