1/11
Technical Bulletin
UTAX
UTAX
UTAX
CD 5025
P
CD 5025P
CD 5030
P
TA
TA
TA
DC 6025
P
DC 6025P
DC 6030
P
TB-37B
2MW-E218/M Date:
09-01-2015
Priority:
…
A
highest priority / …
B
second priority / …
C
other /
S
…
Service Information
Corrective measures for the Document Processor frame damage
T
OPIC
:
If the DP is pressed with an excess force while setting thick book originals,
the left side hinge section of the DP frame might be broken.
Thus, the following set parts are set up for field measures. In case the DP
frame is broken, the jam J9000 or J9001 (*) might occur.
(* J9000: DP no original feed jam / J9001: DPDP original conveying jam)
P
ARTS FOR FIELD MEASURES
:
BUNDLED IN
P
ARTS
B
ASE ASSY
:
Left side hinge
SHEET LEFT GUIDE F
183,5mm
SHEET LEFT GUIDE R
121,8mm
No.1
1
PARTS BASE ASSY SP
Included:
1) FRAME ASSY
2) SHEET LEFT GUIDE F (303M824170)
3) SHEET LEFT GUIDE R (303M824180)
FRAME ASSY