Section
Item
Maintenance item contents
Initial
No.
setting*
2AV/X
1-4-54
1-4
High voltage
Developing
Fixing and
cleaning
Operation
panel and
support
equipment
Mode setting
U100 Setting the surface potential
184
U101 Setting high voltages
• Developing bias
193/38
• Transfer voltage
115
• Transfer voltage output timing
–176
U109 Setting the drum type
H
U110 Checking/clearing the drum count
—
U111 Checking/clearing the drum drive time
—
U130 Initial setting for the developer
—
U131 Setting the toner sensor control voltage
155
U132 Replenishing toner forcibly
—
U135 Checking toner feed motor operation
—
U155 Displaying the toner sensor output
—
U156 Changing the toner control level
• Toner feed start level
100
• Toner empty level
44
U157 Checking/clearing the developing drive time
—
U158 Checking/clearing the developing count
—
U161 Setting the fixing control temperature
• Primary stabilization fixing temperature
135
• Secondary stabilization fixing temperature
160
• Regular stabilization control temperature
180
• Temperature to be deducted from the regular control temperature
0
when copying onto small-sized paper
U162 Stabilizing fixing forcibly
—
U163 Resetting the fixing problem data
—
U196 Turning the fixing heater on
—
U199 Checking the fixing temperature
—
U200 Turning all LEDs on
—
U203 Operating DF separately
—
U204 Setting the presence or absence of a key card or key counter
—
U207 Checking the operation panel keys
—
U243 Checking the operation of the DF motors
—
U244 Checking the DF switches
—
U250 Setting the maintenance cycle
100
U251 Checking/clearing the maintenance count
—
U252 Setting the destination
Japan
U253 Switching between double and single counts
Double count
U254 Turning auto start function on/off
On
U255 Setting auto clear time
120
U256 Turning auto preheat/energy saver function on/off
On
U258 Switching copy operation at toner empty detection
Single mode,
70
U260 Changing the copy count timing
After ejection
U265 Setting the destination specifications
0
U332 Setting the size conversion factor
—
U342 Setting the ejection restriction
On
U344 Setting preheat/energy saver mode
Energy star
U345 Setting the value for maintenance due indication
0
U348 Setting the copy density adjustment range
Normal