USR-N540 User Manual www.usriot.com
Jinan USR IOT Technology Limited 52 / 73 [email protected]
3.7.13.
Webpage Port
USR-N540 has built-in webpage server and the port is 80. Also the port can be revised and visit the web via revised
port.
3.7.14.
Revise MAC
User can check software’s MAC address. USR-N540 MAC is Globally Unique. Also it support customized MAC.
3.7.15.
Firmware Upgrade
Firmware upgrade is fulfilled via network. For details, please refer to Chapter 5.1 configure parameter with
configuration software.
3.7.16.
Flow Control RTS/CTS & XON/XoFF
Flow control: the way for serial port to flow control, can choose enable 485 mode to control 485 transceiver or not.
It is default to enable 458 control mode in the 3031 and the later version, enable 485 mode if you do not choose the
hardware control.
None: default serial port mode. In this mode enable the control for 485 in 3031 and the later mode.
RTS/CTS: Hardware flow control function. It is disabled by default. Don’t enable it if device doesn't support
Hardware flow control .
Notes:
It is only run under RS232 port.
XoN/XoFF: Software flow control function. It is disabled by default. In this mode, the command character of serial
port sends data is 0x11. 0X13 is not allowed.
By the flow control , user can deal with the data that serial port received or sent. If the buffer more than the
threshold value, inform the remote serial port stopping. After the serial port buff, inform remote serial port to deal the
data.
Generally, receiving on the serial port and dealing need some time.
3.7.17.
Reload
Cut off power firstly.
Press “reload” and supply power. Then keep pressing reload for 5 seconds.