USR-K6 User Manual www.usriot.com
Jinan USR IOT Technology Limited 99 / 107 [email protected]
Function: setting /query heartbeat package send way
Format: query:
AT+ HEARTTP <CR>
<CR><LF>+OK=< type ><CR><LF>
setting:
AT+ HEARTTP =< type ><CR>
<CR><LF>+OK<CR><LF>
Parameters:
Status:
NET: send heartbeat package to server
COM: send heartbeat package to serial port
E.g.: AT+HEARTTP=NET
29.
AT+HEARTTM
Function: setting /query time of heartbeat package
Format: query:
AT+ HEARTTM <CR>
<CR><LF>+OK=< time ><CR><LF>
setting:
AT+ HEARTTM =< time ><CR>
<CR><LF>+OK<CR><LF>
Parameters:
Time: heartbeat time ,default is 30s, range from 1 to 65535s.