AT+ RSTIM =< time ><CR>
<CR><LF>+OK<CR><LF>
Parameters: time: short connection time: 0, 60-65535s
E.g.: AT+RSTIM =3600
38.
AT+ MAXSK
Function: setting /query the maximum number of the client that TCP Server connected Format: query:
AT+ MAXSK <CR>
<CR><LF>+OK=< num ><CR><LF>
setting:
AT+ MAXSK =< num ><CR>
<CR><LF>+OK<CR><LF>
Parameters: num: the maximum number of the client that TCP Server connected, range from 1 to 16
E.g.: AT+MAXSK =4
39.
AT+ MID
Function: setting /query module name
Format: query:
AT+ MID <CR>
<CR><LF>+OK=< name ><CR><LF>
setting:
AT+ MID =< name ><CR>
<CR><LF>+OK<CR><LF>
Parameters: name: module name, maximum 15 bytes and can not be none.