USR-K6 User Manual www.usriot.com
Jinan USR IOT Technology Limited 66 / 107 [email protected]
Uc Mod Name
14
55 53 52 2D 4B 32 00
00 00 00 00 00 00 00
Mod Name
Protocol reserve
2
00 00
0
username
6
61 64 6D 69 6E 00
username
password
6
61 64 6D 69 6E 00
password
Uc Net Send Time
1
00
Not enable,reserve the protocol
Ui Id
2
01 00
device ID
Uc Id Type
1
00
8
th
is 1: RFC2217 on, 0: RFC2217 off:
7
th
is 1: index on: 0: index off:
6
th
is 1: link light on: 0: link light off:
5
th
is 1: reset on: 0: reset off
2
th
is 1: send data carry ID: 0: off
1
th
is 1: build connection send ID: 0: off
mac_add rs
6
D8 B0 4C 11 22 33
Device MAC address
DNS Gateway IP
4
01 00 A8 C0
DNS server address
TC_sh_time
1
03
The time for short connection
Uc Reserved
3
00 00 00
Not enable,reserve the protocol
Form 5.1.2-2 Basic Parameter Web Setting
⑥
Serial port parameters command
There are 63 bits to setting net port and serial port parameters, so this command is of high value. Here is a
example to show how to use:(sending 63 bits): FF 52 0 4C 46 35 CA 61 64 6D 69 6E 00 61 64 6D 69 6E 00 00 C2 01 00
08 01 01 01 00 00 00 00 8C 4E 2A06 D8 B 20 31 39 32 2E 31 36 38 2E 31 2E 31 33 33 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 85 01 A8 C0 01 03 00 04 10 0E 00 00 00 00 00 00 00 16, parity bits algorithm: 16 = 52 + 06 + ... + 00;