DAX-‐16 Installation & Operation Manual
Rev 1.4
8
•
Bypass circuitry including passive crossover
Specifications
•
Analog Audio Output
o
Nominal level: 300mV RMS with -‐26dBFS tone input
o
Maximum level: 15Vrms (0dB FS input with +8dB trim)
o
Noise (A-‐weighted): less than 80dB below nominal output level
o
Dynamic range: 106dB or greater
o
Frequency response: 20Hz – 20kHz, +/-‐0.2dB
o
THD: < 0.01% at -‐1dB FS input
o
Source impedance: 50 ohms in series with 5uF
o
Load impedance (recommended): 10k or higher
o
Connectors: 8 DE-‐15 with two channels per connector
•
Amplifier Returns:
o
16 amplifier returns on 8 DE-‐15 amplifier connectors
o
Levels can be monitored
o
Returns can be listened to on audio stream
•
Ethernet: 10/100Mbps
•
AES/EBU
o
16 Channels (8 pairs) on two RJ45 connectors
o
Sample rate: 48k or 96k
•
Harman BLU link
o
Sample rate: 48k or 96k
o
Each output can select from any BLU link channel (256 at 48k, 128 at 96k)
•
Web browser UI
o
Shows 16 bar graphs of output levels or amplifier return levels
o
Audio streaming with ADPCM or PCM with no plug-‐ins on most browsers
o
System configuration screens
•
Bypass audio
o
Analog input drives select outputs on loss of digital input
o