background image

   

DAX-­‐16   Installation   &   Operation   Manual   

   

Rev   1.4   

   

10   

 

Browser  Support

  

   
The   DAX-­‐16   uses   new   features   of   HTML5.   It   streams   audio   using   ADPCM,   which   results   in   25%   of   the   
bandwidth   required   for   PCM.   It   also   streams   audio   using   PCM   if   bandwidth   is   available.   The   DAX-­‐16   uses   
the   “range”   control   on   the   audio   configuration   page   for   setting   output   trim   levels.   Different   browsers   
support   range   in   different   ways.      

 

The   DAX-­‐16   works   well   with   most   modern   web   browsers.   The   table   below   lists   the   characteristics   of   
several   browsers   when   operating   the   DAX-­‐16.   The   DAX-­‐16   decodes   ADPCM   in   javascript   on   most   
browsers   so   no   plugin   is   required.   Browsers   that   cannot   decode   ADPCM   in   javascript   will   generally   be   
able   to   decode   it   with   a   plugin   (such   as   QuickTime   or   VLC).   

 

OS   

Browser   

Audio   Streaming   

Output   Trim   

Android   

Chrome   35.0   

ADPCM   supported.   

New   level   sent   on   untouch   after   slide   

Android   

Dolphin   11.0.1   

PCM   supported   

New   level   sent   during   slide   

Android   

Firefox   30.0   

ADPCM   and   PCM   
supported.   

New   level   sent   on   untouch   after   slide   

Fedora   19   

Arora   0.11.0   

PCM   supported.   

New   level   sent   during   slide.   

Fedora   19   

Firefox   30.0   

ADPCM   and   PCM   

supported.   

New   level   sent   on   mouse   up.   When   using   

arrow   keys,   new   level   sent   on   tab   away.   

Fedora   19   

Midori   0.5.5   

PCM   supported   

New   level   sent   during   slide.   

Fedora   19   

Rekonq   2.4.2   

PCM   supported   

New   level   sent   during   slide.   

Fedora   19   

SeaMonkey   2.26   

ADPCM   and   PCM   
supported.   

New   level   sent   on   mouse   up.   When   using   
arrow   keys,   level   sent   on   tab   away.   

Fedora   19   

Web   3.8.2   

PCM   supported.   

New   level   sent   during   slide   or   arrow   key   
push.   

iOS   

Chrome   35.0   

ADPCM   supported   

New   level   sent   during   slide.   

iOS   

Safari   

ADPCM   supported   

New   level   sent   during   slide.   

OSX   

Chrome   35.0   

ADPCM   supported   

New   level   sent   on   mouse   release.   

OSX   

Safari   6.1.4   

ADPCM   and   PCM   
supported   

New   level   sent   during   slide.   

Windows   

IE   11   

ADPCM   supported   

with   QuickTime   
plugin.   

Trim   controls   do   not   display   correctly.   

Arrow   keys   can   be   used   to   adjust.   

Windows   

Firefox   31.0   

ADPCM   and   PCM   
supported.   

New   level   sent   on   mouse   release   or   tab   
away   from   control.   

Windows   

Chrome   35.0   

ADPCM   and   PCM   
supported.   

New   level   sent   on   mouse   release   or   arrow   
key.      

Windows   

Opera   22.0   

ADPCM   supported.   

New   level   sent   on   mouse   release   or   arrow   
key.   

 

   

 

Summary of Contents for DAX-16

Page 1: ...181 Bonetti Dr San Luis Obispo CA 93401 USA 1 805 549 0161 Office 1 805 549 0163 Fax DAX 16 Installation and Operation Manual...

Page 2: ...ent Class 6 Disposal and Recycling 6 Introduction 7 Features 7 Specifications 8 Model Numbers 9 Browser Support 10 Front Panel 11 Rear Panel 11 DAX 16 Output Assignments 12 DAX 16 Installation and Con...

Page 3: ...as radiators heat registers or stoves Provide proper ventilation The operating temperature range is between 0 C and 40 C The humidity range is between 20 and 80 non condensing The cooling method is c...

Page 4: ...iateurs registres de la chaleur po les ou amplificateurs Fournissez Ventilation Ad quate La temp rature dufonctionnement devrait tre entre 0 C et 40 C L humidit devrait tre 20 et 80 La m thoderefroidi...

Page 5: ...t sollte sein 20 und 80 Die erfrischend Methode ist durch Konvektion und einen innereren F cher Bleiben Sie Produkt Oberfl chen reinigen und Trocken Trennen Sie das Macht Kabel von der Macht Quelle vo...

Page 6: ...hnology Video and similar Electronic Apparatus IEC 60950 Safety Requirements CE UL cUL Safety and Overall Compliance VDE Certified Power Cords Pollution Not intended for environments where conductive...

Page 7: ...audio from the multiple units Outputs can be named by the user to indicate a speaker position and band for applications where the crossover is in the sound processor Buttons and level indicators take...

Page 8: ...h two channels per connector Amplifier Returns o 16 amplifier returns on 8 DE 15 amplifier connectors o Levels can be monitored o Returns can be listened to on audio stream Ethernet 10 100Mbps AES EBU...

Page 9: ...available in two different versions as shown in the table below Model Inputs DAX 16S 16 channels of AES EBU on two RJ45 connectors Analog bypass on pluggable terminal strip DAX 16N 256 channels 48kHz...

Page 10: ...touch after slide Fedora 19 Arora 0 11 0 PCM supported New level sent during slide Fedora 19 Firefox 30 0 ADPCM and PCM supported New level sent on mouse up When using arrow keys new level sent on tab...

Page 11: ...te failure If the button is pressed momentarily after the system has powered up after the front panel LEDs have stopped flashing the configuration on the SD card is copied into the system and to flash...

Page 12: ...will behave when the DAX 16 is in bypass loss of digital input The DAX 16 bypass circuitry contains a passive crossover that supports full range biamp and triamp operation The system is intended to dr...

Page 13: ...has analog outputs Use the left channel analog output as a bypass output 5 Open a web browser on the laptop computer Enter 169 254 1 12 in the address field The home page see figure 1 should appear If...

Page 14: ...In BLU link systems connector A is the IN port and connector B is the OUT port The IN port should be connected to the OUT port of the previous device in the loop The OUT port should be connected to th...

Page 15: ...DAX 16 Installation Operation Manual Rev 1 4 15 Figure 6 DAX 16 audio configuration page...

Page 16: ...o reduce pumping and the release time can be decreased to increase the average volume 17 If desired sent Bypass on digital input loss to Enabled An analog bypass signal fed to the DAX 16 on the rear p...

Page 17: ...card If this page says Could not initialize SD card or some other error message ensure an SD card is in place and that its write protect is not enabled SD cards are write protected or locked when the...

Page 18: ...utput level on each channel The buttons below the bars are labeled with channel and band information provided during system configuration Pressing the buttons enable and disable audio from that channe...

Page 19: ...T will show the cause of the error Clicking on the BLU link status box will bring up a page of BLU link registers that can help troubleshoot any issues Firmware Updates USL may issue firmware updates...

Page 20: ...M 8E 10 Signal Ground reference for Vmon and Imon 11 Channel B input 12 No Connect 13 Channel B Vmon output voltage monitor 14 Channel B Imon output current monitor not used by DAX 16 15 No Connect RJ...

Page 21: ...find most USL products on your network Double click on the product to open a web browser pointed to that product Appendix C System Restore The DAX 16 has a restore button on the front panel It can be...

Page 22: ...by it will be free from defects in material and workmanship under normal usage over a period of one 1 year after its purchase new from and authorized dealer Our obligation under this warranty is limit...

Page 23: ...nual Revisions Rev Description Date 1 0 Original manual 140707 1 1 Formatting Standardized 140709 1 2 Fixed typos changed LED threshold added specifications 140714 1 3 Revise info on bypass 140715 1 4...

Page 24: ...DAX 16 Installation Operation Manual Rev 1 4 24...

Reviews: