Just like the auto-calibration method, the LED current is limited to 90% of its
maximum value on this page in order to give room to increase the current as the
LED heats up, in order to maintain a constant output over time. The measured UV
output on the operator menu will use the selected unit of measurement.
Control Mode Menu
The device operates in two control modes –
Timer Control
and
External Control
.
Timer Control Mode
is the default setting. In this mode, pressing the start button
on the operator menu or pressing an attached footswitch will turn on the UV output
for a set amount of time. Pressing the pedal/start button while the UV output is
active turns off the output immediately.
External Control Mode
disables the operator menu start button. Instead, the
UV output is exclusively controlled by holding down an attached footswitch or
PLC input. Holding down the pedal turns on the output, and releasing the pedal
immediately turns it off.