usha AIR KING Instruction Manual Download Page 8

USE & OPERATION

HOOSE CONNECTOR

FILLING WATER (CONTINUOUS WATER SUPPLY CONNECTION)
Connect water pipe to the continuous water supply
connector located on the lower right side panel. 
Secure the connector with the pipe so that there is 
no leakage and turn on the water supply.

With the help of the water auto-refill mechanism, 
water inside the tank will refill automatically.

Every time the water comes below the minimum level, the water float valve will 
detect it and will start the water flow inside the tank. In the same way it also stops 
water in-flow when reaching the maximum level.
This is an automated process and will not require you to refill the water tank 
manually.
Plug the unit into the power supply and turn the unit on.

INSTALLING HOSE ADAPTER AND FLOAT VALVE
•   Connect the garden hose Connector and turn on the water.
•   Verify water tight connections by visually examining.

FILLING WATER
Water can be filled into the air cooler by:
Continuous water supply (Auto Refill)
Connect a garden hose to the continuous water supply inlet (Reference product 
picture on page 9).

FILLING WATER ( MANUAL)
Do not fill water above the max water level mark.

15

14

REMOTE CONTROL

POWER 

: ON / OFF

FAN 

: Controls fan speed  3 / 2 / 1 / off 

SPEED 

:   Increase fan speed 

 

    Decrease fan speed

COOL

 : Controls cooling or fan operation

SWING 

: Controls the vertical swing movement of louvers

TIMER 

: Controls the timers function for automatic shut off

SLEEP

 : Activate the Smart sleep function

ALARM

 : Deactivate the low water alarm function

CHILD LOCK

 : Activate the child lock function

JUST FOR YOU  : Customisable cooler settings at a touch of button

USE & OPERATION

*Function buttons of remote control is similar to control panel, refer to operation of 
control panel.

The remote control requires AAA (2 x 1.5V) batteries for replacement.
Open the battery compartment at the back of the remote control and insert the AAA 
(2 x 1.5V) batteries inside. Care must be taken to insert the batteries according to 
the correct polarity (+ / –) markings shown inside the battery compartment
Always point the remote control signal transmitter towards the unit when operating. 
Make sure that the signal path is not obstructed.
Remove the batteries if the unit is not going to be used for an extended period of 
time.
Do not drop the remote control.Do not mix different types of batteries such as 
alkaline, carbon-zinc, or rechargeable batteries.
Do not mix old and new batteries.
Exhausted batteries are to be removed from the product.

Summary of Contents for AIR KING

Page 1: ...te www usha com Regd Office Surya Kiran Building 19 Kasturba Gandhi Marg New Delhi India Tel 91 11 23318114 Fax 91 11 23318118 Model CD504A 704A Power rating 190 Watts Rated voltage 230 Volt Rated fre...

Page 2: ...structions carefully before setting up and operating the cooler and please keep this instruction manual for future reference This manual is designed to provide you with important information needed to...

Page 3: ...of minimum 0 5 meters from the wall Not an Air Conditioner Important Please Read The evaporative air cooler is not an air conditioner as it does not use a compressor or refrigerant gas It should not b...

Page 4: ...lative humidity level is 60 or less which allows a noticeable temperature decrease The temperature decrease will be greater in drier climates because higher evaporation occurs when the humidity is low...

Page 5: ...ions DO NOT use in bathrooms Never locate the product where it may fall into a water container Store in a dry area when not in use This appliance is not intended for use by persons including children...

Page 6: ...ly adjust the louvers to change vertical air flow 11 10 SMART SHIELD TECHNOLOGY POWERED BY N9 Water Tank Treated with Anti Bacteria Additive USHA Coolers now come with Smart Shield Technology powered...

Page 7: ...ATION 13 12 FAN SPEED Press the FAN SPEED button repeatedly to change the speed between 1 2 3 The indicator light will show the selected speed 3 HIGH 2 MED 1 LOW There is an increase decrease button o...

Page 8: ...er level mark 15 14 REMOTE CONTROL POWER ON OFF FAN Controls fan speed 3 2 1 off SPEED Increase fan speed Decrease fan speed COOL Controls cooling or fan operation SWING Controls the vertical swing mo...

Page 9: ...IMPORTANT The cooler is supplied with Honeycomb Cooling Media The cleaning frequency for the Honeycomb media depends on local air and water conditions In areas where the mineral content of water is h...

Page 10: ...ging the mechanical knob position of the control panel Motor Faulty Contact Service centre Not Cooling Unit is making noise Pump is not turned ON On control Panel Turn COOL FUNCTION TO ON Low or no wa...

Page 11: ...es 1 The Company will not be liable for any loss or damage arising resulting from indirect or consequential loss or damages 2 The Company aggregate liability in respect of all claims under the Warrant...

Page 12: ......

Reviews: