usha AIR KING Instruction Manual Download Page 7

SMART SLEEP

Press [SMART SLEEP] button to on /off the smart sleep function. 
When smart sleep is on, the fan speed will decrease by 1 step after 
each 2 hrs until it does not reach to minimum speed. This function will 
work only when fan is running above minimum speed. There is a 
green LED to indicate that function is activate or not.

JUST FOR YOU

Press [JUST FOR YOU] button to activate a combination of fan speed, 
pump and swing settings. There are 3 combinations (P1, P2 & P3) 
that can be set as per your desire and also can be stored. To set a 
new combination, press JFU key. The display will show ‘P1’ on first 
press ‘P2’ on second and ‘P3’ on third and red LED will glow solid to 
indicate that function is activated. There are some factory settings 
which are stored initially will be applied when JFU key is pressed. Now 
to set a new combination you want to store/Edit on any program no 
i.e. P1, P2 or P3, follow following steps:
1.  Set program number.
2.  Set your desired combination of fan speed, pump and 

swing.(That time the LED will start blinking. It means that now 
you can store this setting).

3.  Long press JFU key to store the same. A long beep will confirm 

that your setting has been saved.

Note:

 If you don’t press the JFU key when LED is blinking, the new 

settings will not be saved. The function will be deactivated after 1 min 
automatically.

 

USE & OPERATION

13

12

FAN SPEED

Press the FAN SPEED button repeatedly to change the speed 
between 1 - 2- 3. The indicator light will show the selected speed:.
3 (HIGH) 

 2 (MED) 

 1 (LOW)

There is an increase /decrease button on remote to change the fan 
speed

TIMER

Press the TIMER button until the desired time duration setting is 
selected. When the set time has passed, the unit will automatically 
turn off (unit remains in Standby mode until power cord is unplugged 
from electrical socket). The TIMER function allows you to program the 
unit for up to 8 hours of use.

LOW  WATER ALARM

The unit is equipped with a low water sensor. In cool Mode, when 
water in the tank is below the minimum level, you will hear a beeping 
sound and the indicator light will glow solid continuously and the pump 
will be off automatically .
First switch OFF the unit and unplug from the power outlet. Fill the 
water tank with water above the minimum water level mark. Plug in 
and switch ON again.
To deactivate the alarm and continue using the unit as a fan (without 
evaporative cooling), Press the Alarm key. The Low Water Alarm will 
not activate in Fan only mode. The Low Water Alarm will beep again if 
the COOL function is activated while the water tank is still empty. The 
water empty LED above alarm switch will glow continuously in 
absence of water. 

CHILD LOCK

Long press [Child Lock] button  to on/off the function. When child lock 
is on, no key will work either on panel or remote instead of child lock 
key. There is a green LED to indicate that function is activate or not.

USE & OPERATION

Summary of Contents for AIR KING

Page 1: ...te www usha com Regd Office Surya Kiran Building 19 Kasturba Gandhi Marg New Delhi India Tel 91 11 23318114 Fax 91 11 23318118 Model CD504A 704A Power rating 190 Watts Rated voltage 230 Volt Rated fre...

Page 2: ...structions carefully before setting up and operating the cooler and please keep this instruction manual for future reference This manual is designed to provide you with important information needed to...

Page 3: ...of minimum 0 5 meters from the wall Not an Air Conditioner Important Please Read The evaporative air cooler is not an air conditioner as it does not use a compressor or refrigerant gas It should not b...

Page 4: ...lative humidity level is 60 or less which allows a noticeable temperature decrease The temperature decrease will be greater in drier climates because higher evaporation occurs when the humidity is low...

Page 5: ...ions DO NOT use in bathrooms Never locate the product where it may fall into a water container Store in a dry area when not in use This appliance is not intended for use by persons including children...

Page 6: ...ly adjust the louvers to change vertical air flow 11 10 SMART SHIELD TECHNOLOGY POWERED BY N9 Water Tank Treated with Anti Bacteria Additive USHA Coolers now come with Smart Shield Technology powered...

Page 7: ...ATION 13 12 FAN SPEED Press the FAN SPEED button repeatedly to change the speed between 1 2 3 The indicator light will show the selected speed 3 HIGH 2 MED 1 LOW There is an increase decrease button o...

Page 8: ...er level mark 15 14 REMOTE CONTROL POWER ON OFF FAN Controls fan speed 3 2 1 off SPEED Increase fan speed Decrease fan speed COOL Controls cooling or fan operation SWING Controls the vertical swing mo...

Page 9: ...IMPORTANT The cooler is supplied with Honeycomb Cooling Media The cleaning frequency for the Honeycomb media depends on local air and water conditions In areas where the mineral content of water is h...

Page 10: ...ging the mechanical knob position of the control panel Motor Faulty Contact Service centre Not Cooling Unit is making noise Pump is not turned ON On control Panel Turn COOL FUNCTION TO ON Low or no wa...

Page 11: ...es 1 The Company will not be liable for any loss or damage arising resulting from indirect or consequential loss or damages 2 The Company aggregate liability in respect of all claims under the Warrant...

Page 12: ......

Reviews: