Installation
11/20
Fl Remote Set
9
5
Installation
5.1
Placement of the radio water sensors
Place the water sensors on the floor in such a way that in
case of alarm the four golden contact surfaces can come
into contact with water.
5.2
Placement of receiver, splitter and cables
Place the receiver, splitter and all I/O cables higher than
the water sensor to protect them from water in case of
flooding.
5.3
Electrical connection
Plug the I/O receiver cable (10) of the radio receiver (1) into the
Fl I/O connector.
If the connector is already occupied or the cable (10) is too short,
please use the splitter (5) and the I/O connection cable (6)
additionally.
When the I/O plug is plugged into the socket, this must
cause a clicking noise. If not, please check again if the
plug is properly engaged!
When disconnecting connections, please make sure to
press the locking tabs of the I/O connectors!