background image

Version 1.0 

 

Setup 

Before continuing with setup please be sure to read the Safety section of this document.  

Below is the connection diagram for the AC/DC adapter.  

 

 

 

 

 

 

 

 

 

 

The FRS Switches shall be used with a customized AC/DC adapter. Users of the FRS Switch must provide 
their own AC/DC adapter in which the DC side power line is spliced and terminated in a banana plug 
connector on each side of the splice as depicted above. The ground line should not be spliced. 

The FRS Switches have 3 exposed receptacles.  

 

Two banana receptacle connectors to interface with the DC output of an AC/DC power adapter. 

 

One 2.1mm barrel jack receptacle connector used for the control signal. 

The two banana receptacle connectors have corresponding labels above them to indicate which side of 
the splice to connect. Labels will read “AC Adapter” to indicate that the banana plug connector on the 
AC/DC adapter side of the spliced power line be connected here. While the other label will read “to 
UUT” to indicate that the banana plug connector on the DC barrel jack side of the spliced power line be 
connected here. Reversing the orientation can damage the FRS Switch. See example pictures of an FRS 
Switch below with labels above the banana receptacle connectors.  

The 2.1mm Barrel Jack Receptacle is labeled “Control” and is used with a DC signal to enable and disable 
the switch. A corresponding barrel jack plug will be shipped with each FRS Switch. The FRS Switch does 
not come with a control cable. The user must create their own control cable using the barrel jack plug 
included in the shipment.  See example picture of an FRS Switch below with a Control label above the 
2.1mm barrel jack receptacle. 

To UUT 

Positive 

Negative

AC/DC Adapter 

UUT External Power 
Barrel

From DC Side of AC/DC 
adapter 

Summary of Contents for Fast Role Swap

Page 1: ...Version 1 0 Fast Role Swap FRS Switch User Guide ...

Page 2: ...Version 1 0 Contents Introduction 3 Safety 3 Equipment 3 Setup 4 Use 6 Supporting Information 7 ...

Page 3: ...r any extended duration It is strongly recommended that the FRS Switch be connected only for the purposes of running the FRS Compliance tests then disconnected At no point should a user disassemble the FRS Switch Equipment Below is a table of equipment needed to us the FRS switch Additional Equipment Used For Provided By AC DC Power Adapter with DC side power line spliced Terminate splice on each ...

Page 4: ...nnect Labels will read AC Adapter to indicate that the banana plug connector on the AC DC adapter side of the spliced power line be connected here While the other label will read to UUT to indicate that the banana plug connector on the DC barrel jack side of the spliced power line be connected here Reversing the orientation can damage the FRS Switch See example pictures of an FRS Switch below with...

Page 5: ...C power adapter to the FRS switch by connecting the spliced power line on the DC side of the AC DC power adapter to the banana receptacle connectors on the switch following the orientation labels 4 Connect Control cable to barrel jack receptacle labelled Control 5 Connect other end of Control cable to USB IF Approved USB PD Test Equipment 6 Follow USB IF Approved USB PD Test Equipment setup proced...

Page 6: ... table State Control Voltage Banana Receptacles ON 3V 10V Connected OFF All other voltages Not Connected Below drawing depicts the FRS Switch in the ON state when Control voltage is between 3V and 10V It is suggested that a 6 5V control voltage be used 20V 5A DC output 20V 5A DC output Connected Short Control 3V 10V ON Positive AC DC Adapter UUT External Power Barrel ...

Page 7: ...ted that 0V be used Supporting Information The Data Sheet of the Crydom CMX60D20 as well as the Data Sheet for the 2 1mm barrel jack plug and receptacle are included in the zip file with this user guide No Power 20V 5A DC output Disconnected Open Control 0V OFF Positive AC DC Adapter UUT External Power Barrel ...