2. ELECTRICAL CONNECTIONS

Wire size recommended 20 gauge stranded copper

NOTE:

 Identify the type of installation the photo eye is being used for.

A. Monitored Entrapment Device per UL325
B. Vehicular Safety Device

A.  Wiring for Monitored Entrapment Device

installation Receiver

1.  Photo eye “12” vdc connects to the Photo Eye power connection

on the gate operator control board.

2.  Photo eye “0” ground connects to the common ground

connection on the gate operator control board.

3.  Photo eye “C” common connects to the common ground

connection on the gate operator control board.

4.  Photo eye “NC” normally closed connects to the control board

input for the direction of travel you are protecting.

Transmitter

NOTE: No wiring is required if the battery power option is being used, if 
hard wired installation is being used wire as below.

1.  Photo eye 12 vdc connects to the Photo Eye power connection

on the gate operator control board. See figure 3.

2.  Photo Eye ground wires to the common ground connection on

the gate operator control board. See figure 3.

B. Wiring for Vehicular safety Device Installation Receiver

1.  Photo eye “12” vdc connects to the Photo Eye power connection

on the gate operator control board.

2.  Photo eye “0” ground connects to the common ground

connection on the gate operator control board.

3.  Photo eye “C” common connects to the common ground

connection on the gate operator control board.

4.  Photo eye “NO” normally open connects to the control board

“Safety Loop/Reversing Edge input”

Transmitter

NOTE: No wiring is required if the battery power option is being used, 
if hard wired installation is being used wire as below.

1.  Photo eye 12 vdc connects to the Photo Eye power connection

on the gate operator control board. See figure 3.

2.  Photo Eye ground wires to the common ground connection on

the gate operator control board. See figure 3.

WARRANTY

USAutomatic, LLC warrants this product to be free of defects in 

materials and workmanship for 1 YEAR. For a period of 1 

YEAR following purchase USAutomatic, LLC. will repair or 

replace the product free of charge, including parts, shop labor 

and return to customer shipping and handling. This 1 YEAR 

warranty does not cover the plastic case from normal wear or 

damage due to misuse.
To have the product sent for warranty consideration, it must be 

returned with the proof of purchase and a return authorization 

number.  To  obtain  a  return  authorization  number  please  call 

(800) 878-7829 for assistance. The return authorization number

must be clearly marked on the outside of the return package or

it may not be accepted.

USAutomatic LLC

 

3. ALIGNMENT

The RX / Receiver has a red LED which will illuminate when
power is applied to the RX / Receiver. When aligned with the
TX / Transmitter, the red LED will go OFF and the green LED
will come ON. When beam is broken, the red LED will come
ON and the green LED will go OFF.

A feature to assist in the
optimal alignment allows
for a voltmeter to be
connected to the TP- and
TP+ test points located on
the RX / Receiver. With
voltmeter attached use
alignment chart verify the
optimal alignment.

Alignment Chart

TP-/TP+ readings 

DCV

Signal Strength

Red LED Grn LED

0 Vdc

No Signal

ON

OFF

3 Vdc

Minimum useful signal

OFF

ON

5 Vdc

Maximum useful signal

OFF

ON

Once alignment is complete, install the covers using the 4 black 
screws. Install the hood onto each unit.

4. BATTERY INFORMATION

TX / Transmitter battery Requirement

 - Two 3.6 vdc lithium

batteries (model - ER14505) or equivalent. When installing
verify the correct polarity shown in figure 3.

NOTE:  Please dispose of the batteries properly as they are 

hazardous waste.  

ELECTRICAL CONNECTIONS

Fig. 3

Fig. 4

www.USAutomaticGateOpeners.com  |  (800) 878-7829  |  [email protected]