background image

-

Page 5

Programmable System Options:

The following is a description of the programming options. Some program branches control more
than one option, and may require accessing a particular branch number twice in order to program
all desired features. 
1.

Arm Mode:

Selects one of two modes: Manual Arming (with remote only) or Passive Arming

(arms 30 seconds after key is turned off and all doors closed.
2.

Auto Rearming Mode:

When selected, the system will automatically re-arm and lock 30

seconds after it has been disarmed regardless if a door is open or closed.

3.

Ignition Controlled Lock/ Override Code Set:

This dual program branch sets Ignition 

Controlled Locking and programs the optional Emergency Override Code. 
Override Code Set. Changes the Emergency Override Code for a higher level of security.

4.

Ignition Controlled Unlocking:

Selects whether or not the system automatically unlocks the

door  when the ignition is turned off. The Ignition Door Locking feature may be programmed

to unlock all doors or the driver's door only.  If driver's door only is selected, the optional 

Passenger Unlock feature must be connected. 

5.

Door Unlock Pulse:

Selects between one pulse or two pulse operation for the door unlock 

output.  Vehicles that require two pulses on the proper wire to unlock the doors can be
interfaced directly without the use of relays or any additional circuitry by programming the

system for double unlock pulse.

6.

Door Lock Pulse Length:

Selects between a 1, 3 or 0.1 seconds output for door locking and 

unlocking.  Program to 3 seconds for vehicles equipped with vacuum door locking systems. 

7.

Passive Door Locking:

Selects whether or not the system will automatically lock the doors

during Passive Arming.

8.

Ignore Open Door Report:

Bypasses the open zone warning chirps for vehicles equipped

with a residual dome light circuit that remains ON for a period of time after closing the door.

9.

Arming Chirps/Honks:

Selects between normal and silent operation.

10.

Horn Honk with Arm & Disarm:

Enables or Disables Arm/Disarm horn honk 

confirmation.

Disabled:

When selected, the horn will honk only when the alarm is triggered.

Enabled:

When selected, the horn will provide the arm/disarmed trigger indications, 

allowing the siren installation to be skipped. 

11. 

Horn Honk Duration

:

Selects between Short, Normal or Extended horn honks.

12.

Extended Parking Lights:

When selected, the parking lights will remain ON for 30 seconds

after disarming the system.

13.

Aux 2 Auto Activate with Arm:

When selected, the Auxiliary 2 output will activate when

the system is armed.  This feature can be used to roll-up windows, close sunroofs, activate 

accessories, etc.

Summary of Contents for AS62UG

Page 1: ...AS62UG INSTALLERS INSTRUCTIONS ...

Page 2: ...options are available in Dealer Mode Factory Upgrade Mode 1 Turn on the ignition key On Off On Off On Off On Off On Off On Off and back On Key On 6 times 3 seconds later the horn will honk 6 times 2 Press and hold the Override switch for 5 seconds The horn will honk 5 times The system will enter Factory Upgrade Mode and will now operate from the Factory Remotes and or keypads Customer Remote Progr...

Page 3: ...LCD 2 way transmitter the standard transmitter or as a factory upgrade no transmitters all system programming can be performed using either mode To enter System Programming 1 Turn ignition ON 2 Within 5 seconds press the valet switch 5 times The siren horn will provide three chirps indicating that you have entered Programming 3 Press the valet switch the number of times equal to the System Paramet...

Page 4: ...Code 1 Follow steps 1 3 above 2 Press the override switch a number of times equal to the Disarm code and continue holding for 10 seconds on the last press The system will disarm If the code is entered incorrectly turn off the ignition and begin again To set the Emergency Override Code 1 Turn on ignition 2 Within 5 seconds press the valet switch 5 times The siren will provide one long chirp indicat...

Page 5: ...hicles that require two pulses on the proper wire to unlock the doors can be interfaced directly without the use of relays or any additional circuitry by programming the system for double unlock pulse 6 Door Lock Pulse Length Selects between a 1 3 or 0 1 seconds output for door locking and unlocking Program to 3 seconds for vehicles equipped with vacuum door locking systems 7 Passive Door Locking ...

Page 6: ...not available connection of the Disarm Validation Input to the Parking light circuit is necessary In this mode the security system will NOT disarm if the unlock switch is pressed inside the vehicle s door In this mode the Disarm Input and the Disarm Validation Inputs require a positive pulse simultaneously If the door unlock switch in the vehicle is pressed the system will not disarm because the p...

Page 7: ...trigger High Current horn circuits Pin 5 WHITE WIRE Parking Light Output relay Connect the White wire to the circuit that shows 12V or ground only when the parking lights are on and set the internal parking light relay jumper to the proper polarity For parking light circuits exceeding 10 amps a relay is required For vehicle s with independent left and right parking light circuits diodes must be in...

Page 8: ...Connector J6 4 Pin White Connector Plug in connector port for optional sensor Connector J7 Pin 1 RED BLACK WIRE Disarm Validation Input For Type 2 Mode connect to the vehicles unlock motor wire that shows positive or negative when pressing the Factory Remote s unlock button twice usually described as Passenger Unlock Motor For Type 1 Mode connect to the vehicle s parking light circuit Disabled Mod...

Page 9: ...k All Unlock Driver Only Off 5 Door Unlock Pulse Single Double 6 Door Lock Pulse Length 1 second 3 seconds 0 1 seconds 7 Passive Door Locking Disabled Enabled 8 Ignore Open Door Report Off Ignore 9 All Chirps Honks Enable Disable 10 Horn Honk Enable Disable 11 Horn Honk Length Short Normal Extended 12 Parking Lights Mode Normal 30Sec ON 13 Aux 2 Auto Activate Disabled Enabled 14 Aux 1 Mode Pulsed ...

Page 10: ...AS62UG Not Used ...