Calibration
C06
0 = calibration not needed
1 = Ready to calibrate with one calibration
weight
2= Ready to calibrate using multiple
calibration weights (Linear)
3 = Sensitivity Output
Restore Default Settings
C07
0 = do not restore
1 = restore to default settings
Warning Tone
C08
0 = turn off warning tone
1 = turn on warning tone
Automatic Power Off
C09
0 = turn off auto power off
10 = power off automatically if no
change within 10 minutes 30 = power
off automatically if no change within 30
minutes 60 = power off automatically if no
change within 60 minutes
Power Saving Mode
C10
LED Version OP900A:
0 = turn off power saving setting
3 = turn off display if no change within 3
minutes
5 = turn off display if no change within 5
minutes LCD Version OP900B:
0 = turn off the backlight
1 = backlight only when the weight changes
or keyboard is pressed2 = constant
backlight
Hold Function
C11
0 = turn off hold function
1 = Peak hold - Grabs the highest weight
2 = Manual hold - Grabs the current weight
3 = Auto hold - Automatically holds data
when stable
4 = Average hold - for animal weighing,
averages the weight from a sample of 3
seconds
5 = Auto Average hold - Average hold
without the need to press the hold key
Unit Conversion
C12
see table 2
Upper Limit Alarm
C13
Set upper limit within the max. capacity
Lower Limit Alarm
C14
Set lower limit within the max. capacity
Inner Code Display
C15
check the inner code (raw data)
Set Date
C16
Set date from left to right: year/month/day
Set Time
C17
Set the time from left to right: hour/
minute/second