3
Proper Installation
This water system must be properly installed and located in accordance with the
Installation Instructions before it is used or the warranty will be void.
•
Do not
install or store where it will be ex-
posed to temperatures below freezing or
exposed to any type of weather. Water
freezing in the system will break it. Do not
attempt to treat water over 100°F.
•
Do not
install in direct sunlight. Excessive
sun or heat may cause distortion or other
damage to non
-
metallic parts.
•
Properly ground to conform with all gov-
erning codes and ordinances.
•
Use only
lead
-
free solder and flux
for all
sweat
-
solder connections, as required by
state and federal codes.
•
Maximum allowable inlet water pressure is
125 psi. If daytime pressure is over 80 psi,
night time pressure may exceed the maxi-
mum. Use a pressure reducing valve to
reduce the pressure.
•
WARNING:
Discard all unused parts and
packaging material after installation. Small
parts remaining after the installation could
be a choke hazard.
Before Starting Installation
Tools, Pipe, and Fittings, Other Materials
•
Channel Locks
•
Screwdriver
•
Teflon tape
•
Razor knife
•
Two adjustable wrenches
•
Additional tools may be required if modifi-
cation to home plumbing is required.
•
To maintain full valve flow,
1”
pipes to and
from the system fittings are recommended.
The outlet pipe should be the same size,
or a larger than the water supply pipe.
•
Use copper, brass, or PEX pipe and fit-
tings.
•
Some codes may also allow PVC plastic
pipe.
•
ALWAYS install the included bypass valve,
or install a 3 shut
-
off valve hard piped by-
pass. Bypass valves allow the water to be
turned off to the system, but can still pro-
vide water to the house for water use dur-
ing repairs or service.
•
5/8”
OD,
1/2”
ID drain line is needed for
the valve drain.