6
Any solder joints being soldered near the valve must be done before connecting any piping
to the valves. Always leave at least 6" (152 mm) between the control valve and joints being
soldered when soldering pipes that are connected to the valves. Failure to do this could
cause damage to the valves.
The Aquatrol Backwashing Filter is equipped with 3/4” male connections. Teflon tape
should be used to seal the threads when the plumbing is attached.
The inlet and outlet can be identified on the bypass valve. There are arrows stamped in the
bypass valve showing flow direction. The arrow pointing toward the valve is the inlet and the
arrow pointing away from the valve is the outlet
1.
Apply Teflon tape to the inlet connection and install the inlet and outlet plumbing
.
All piping should be secured to prevent stress on the bypass valve and connectors.
Aquatrol Carbon Tank Installation Instructions
Installation, Operation and Maintenance Manual
AQF-CX-100 & AQF-CX-200