Installation Instructions 

200-SENTRY-IX Water Treatment System 

Page 9 

3.  Once the valve is installed, connect the green 3/8” tubing 

to the tank valve install the locking clip.  Leave the other 
end of the tubing loose for now, it will be connected later in 
the installation. 

 
 
 
 
 
 
 
 
 

NOTE:  Tanks  are  pre-pressurized  at  7  psi.  Prior  to  installation, 

check, add or release as required. 

 

 

E. RO Filters and Membrane Installation 
 

1.  Install  the  sediment  filter  in  the  first  sump.    When 

facing the unit, this would be the far right sump. 

2.  Remove  the  first  sump  from  the  system  and  install 

the sediment filter in the sump.  

3.  Tighten  the  far  right  sump  hand  tight  and  secure  it 

with  the  supplied  filter  wrench  by  turning  it  an 
additional 1/4  - 1/2 turn. 

Summary of Contents for 200-SENTRY-IX

Page 1: ...STEM Visit us online at www uswatersystems com REVISION 1 0 REVISION DATE June 6 2018 US Water Systems Corporate Office 1209 Country Club Road Indianapolis IN 46234 1 800 608 8792 info uswatersystems...

Page 2: ...STOP TANK VALVE TUBING Parts Check List RO Module DI Module UV and Monitor Tubing Bundle Filter Wrench Drain Saddle Tank Valve Angle Stop Feed Valve Tank and Side Mount Tank Stand Pre and Post Filters...

Page 3: ...d pre filters and membranes A BRACKET is provided so they may be mounted typically below sink There is a dual filter housing systems which holds the DI filters cartridges DI Filter Housings are used t...

Page 4: ...unit where temperatures fall below freezing otherwise damage will result Guidelines for component placement are as follows STORAGE TANK may be placed where it is convenient within five feet of the RO...

Page 5: ...Proceed with mounting the faucet FEED WATER CONNECTION is accomplished with an angle stop feed water valve This valve will be installed in the cold water line between the sink cold water shutoff valve...

Page 6: ...tened 2 Once the faucet is secure install the 7 16 UNS x 3 8 QC faucet connector on the threaded nipple This fitting doesn t require sealant This fitting will seal at the beveled surface Tighten the f...

Page 7: ...ter that is spilled Now install the angle stop valve on the sink faucet shutoff valve and tighten it Don t worry about the angle stop valve position because it will swivel and can be positioned later...

Page 8: ...is recommended Install rubber gasket on this half of the drain saddle Be sure the gasket hole is lined up with the port hole 2 Drill 1 4 hole at mark through one side of pipe BE CAREFUL not to drill t...

Page 9: ...tallation NOTE Tanks are pre pressurized at 7 psi Prior to installation check add or release as required E RO Filters and Membrane Installation 1 Install the sediment filter in the first sump When fac...

Page 10: ...hten the center sump hand tight and secure it with the supplied filter wrench by turning it an additional 1 4 1 2 turn 6 Remove the far left sump and install the chloramine filter not pictured yellow...

Page 11: ...ing with little effort Refer to connections instructions on Page 16 2 Use the supplied wrench to remove the membrane housing cap 3 Remove the membrane from the protective packaging and install it in t...

Page 12: ...ng screws and install screws allowing the mounting bracket slots to slip over them NOTE If the cabinet sidewalls are not solid unit may sit on the floor with screws to keep it against the cabinet in a...

Page 13: ...ply valve to RO unit at the sediment filter inlet fitting 4 Connect the tubing from the drain saddle to the RO unit at the flow restrictor on the membrane 5 Mount the DI system to the wall Attach the...

Page 14: ...e air in it Typically the standard startup procedure will be sufficient but in some cases due to the water temperature and pressure additional air bleeding must be performed The following procedure wi...

Page 15: ...amber BE SURE not to touch the UV bulb glass Wear rubber gloves if possible 2 Install the plug on the UV light bulb Make sure it is fully attached and push the UV light bulb into the chamber 3 Push th...

Page 16: ...ite fiber type filter is installed in the INLET sediment filter sump Lubricate the o ring at the top of the sump with a small amount of the silicone included Tighten the filter sump hand tight then us...

Page 17: ...d time At this point supply line to ice maker connection optional may be opened Once the system has been purged of air and is fully operational install the DI cartridges in the housings 1 Shut off the...

Page 18: ...as measured in gallons per day gpd or milliliters per minute ml min Using a graduated cylinder the formulas are REJECT RATIO The reject ratio is the amount of water produced compared to the amount of...

Page 19: ...ly into the tube stop 3 Push up to the tube stop Push the tube into the fitting to the tube stop The collet gripper has stainless steel teeth which hold the tube firmly in position while the O ring pr...

Page 20: ...Installation Instructions 200 SENTRY IX Water Treatment System Page 20 Green Tube...

Page 21: ...Installation Instructions 200 SENTRY IX Water Treatment System Page 21...

Page 22: ...Installation Instructions 200 SENTRY IX Water Treatment System Page 22...

Page 23: ...Installation Instructions 200 SENTRY IX Water Treatment System Page 23...

Page 24: ...mage to the membrane or filters caused by iron sulfur bacterial iron silt sand tannins organics bacteria hot water or chlorine voids the warranty on the membrane These warranties are in lieu of all ot...

Reviews: