F. Membrane Installation
1. Remove the 1/4” tubing from the membrane housing cap
by pressing the collet on the elbow fitting toward the fitting.
When the collet is flush with the fitting, the tubing will pull
out of the fitting with little effort. Refer to connections
instructions on Page 16.
2. Use the supplied wrench to remove the membrane
housing cap.
3. Remove the membrane from the protective
packaging and install it in the membrane housing.
There are two O-rings on end of the middle
membrane tube. Lightly lubricate these O-rings with
the supplied silicone grease.
4.
BE SURE
the membrane is fully seated in the
housing. If the membrane is fully seated, it will
about 1/8 - 1/4 inset from being flush with the
housing.