 PrS = Commanded Line Pressure

 

Indicates the transmission line pressure that the controller is currently 
commanding in PSI. These values are based upon the normal OEM parameters 
for the pressure control solenoid and main regulator valve line-up for the selected 
transmission. The actual line pressure may vary from this value, especially if 
changes have been made to the main pressure regulator valve, the main 
regulator valve spring, the main regulator boost valve, or the pressure control 
(EPC) solenoid.

 

 

 

tbL = Table

 

Shows the currently selected table (TB1, TB2, TB3, or TB4) after showing "TbL" 
for 2.5 seconds. Pressing the knob once displays "SLT" for 2.5 seconds to show 
that the table can be manually selected. In select mode, you can rotate the knob 
to  select  "rES",  "tb1",  “tb2”,  “tb3”,  “tb4”.  rES  stands  for  "Remote  Select"  and 
indicates  that  the  table  is  selected  remotely  by  the  table  select  input.  Remote 
Select  mode  is  the  power-on  default.  You  can  select  tables  1-4  to  override  the 
table  select  input  and  force  the  Quick  4  to  use  a  specific  table.  Once  you  have 
selected  the  desired  table  or  mode,  you  can  exit  select  mode  by  pressing  the 
knob once. "rET" will then be displayed for 2.5 seconds to indicate that you have 
returned from select mode. The selected mode will be retained until the ignition is 
turned off or until you change it. 

 

 

tnE = Tuning Mode

 

Allows  the  most  commonly-used  settings  (such  as  TPS  calibration  and  shift 
points)  to  be  adjusted  directly  on  the  controller.  Press  the  knob  once  to  enter 
Tuning Mode. Please see the “Tuning Menu Options” section for the details of the 
tuning mode menu. Upon entering tuning mode, a copy of the currently-selected 
table is created to be used as a “scratchpad” for editing, and the controller begins 
running  off  of  this  copy  during  the  tuning  session.  This  allows  you  to  see  the 
effects  of  your  changes  immediately,  which  eliminates  guess-work.  We  refer  to 
this functionality as "Live Editing". Another benefit of live editing is that the original 
calibration  is  preserved  until  you  explicitly  save  your  changes.  This  allows  safe 
experimentation  without  modifying  any  of  your  existing  settings.  If  you  don't  like 
the  results  of  your  changes,  simply  exit  the  tuning  menu  with  the  Discard  (dIS) 
option  or  turn  off the ignition. This  will  erase  your  changes  and  reset  everything 
back to where it was before you entered tuning mode. 

 

   

 SrE = Software Revision

 

Indicates the software and hardware revision of the controller. 
"MajorRev.MinorRev.HardwareRev" (ie: 4.0.3) 

 

Summary of Contents for Quick 4

Page 1: ...On Board Diagnostic and Tuning Interface...

Page 2: ...ectronic Controls LLC vF4 0 1 Copyright 1997 2017 by Baumann Electronic Controls LLC All rights reserved WARRANTY Baumann Electronic Controls LLC is dedicated to producing the highest quality products...

Page 3: ...knob The mode name is also displayed at any time when the function knob is pressed in in all modes other than Status and Tuning modes OFF In this mode the display is blank and nothing is shown StA Sta...

Page 4: ...gnition is turned off AUt Automatic Select Indicates that you have left manual gear select mode and are back in automatic transmission mode When in manual select mode click the function knob to return...

Page 5: ...ill then be displayed for 2 5 seconds to indicate that you have returned from select mode The selected mode will be retained until the ignition is turned off or until you change it tnE Tuning Mode All...

Page 6: ...it later without needing to do another learning cycle ERROR CODES If there is an error the codes for various conditions will be displayed in alternating 2 5 second intervals with the current display...

Page 7: ...TFT sensor voltage is too high The TFT sensor circuit could be open Hot The temperature in the transmission is above the allowed threshold which can be adjusted in the tuning software F OS The Output...

Page 8: ...n adjustment mode you can double click the knob press it twice quickly to automatically set this value to the current TPS voltage Make sure that the throttle plate accelerator pedal or injector pump i...

Page 9: ...ain to return to the menu LtU Light Throttle Upshift This setting is used to adjust the light throttle shift RPM for all shifts The value shown is the approximate closed throttle RPM for the 2 3 upshi...

Page 10: ...hift feel If you are in doubt try higher values for this setting Press the knob once to enter adjustment mode and change this setting Press again to return to the menu SPO Speedo Output One press of t...

Page 11: ...11...