COURIER HIGH SPEED MODEMS
Summaries and Tables B-25
Register
Default
Function
S39
−
S40
0
Reserved.
S41
0
Sets the number of allowable remote
access login attempts, thus enabling or
disabling remote access. The default
setting of zero allows no remote login
attempts, thus disabling remote access. A
value of 1 or greater enables remote
access. If the number of unsuccessful
login attempts exceeds the limit set by this
register, the modem returns online and
any further login attempts during the
remainder of that connection are refused.
S42
126
Stores the ASCII decimal code for the
remote access escape character. The
default character is a tilde (~).
S43
200
Sets the duration, in fiftieths of a second,
of the guard time for the remote access
(~~~~) sequence.
S44
15
Sets the duration, in seconds, of the delay
between when the modem senses loss of
carrier and when it attempts to re-
establish a leased-line connection.
S45
−
S50
0
Reserved.