- 12 - 

Stove Operation 

Before using the stove for the first time, use a mild detergent to wipe it clean. 

Do not 

use corrosive or abrasive detergents.

 

Turn the burners on about 15-20 minutes before broiling for preheating, according to 

the cooking requirement to adjust the flame size. 

Notice: When first preheating, the furnace will smoke above. This is caused by 

protective lipids on the grates and other parts are heated, it is normal, and it will be 
eliminated after the power up to the maximum for burning an hour. 

 

Exchange main fire nozzle to switch gas source 

Remove control panel, cooking grates, the pilot light head, and burner. Remove 

main fire nozzle with proper open spanner. Exchange nozzle of another gas source. 
Reinstall burner, the pilot light head, cooking grates and control panel in proper order.   

 

Caution: Each main fire orifice of the burner has been installed before delivery, 

normal use without adjustment but only switching gas. Adjust only by authorized and 
licensed technicians. When you converse the gas source, exchange the corresponding 
pressure maintaining valve which installed on air intake. See 2 in P17. 

 

Adjust air input 

Remove control panel, unscrew damper solid screw (Fig.6), revolve damper left to 

right (Fig.7), meanwhile, observe flame, to adjust to an appropriate opening degree. Then 
screw damper solid screw, make sure the equipment will not get loose in the process of 
moving and transition. Reinstall control panel. 

 

Caution: Each burner damper has been adjusted before delivery (once air input), 

normal use without adjustment but only switching gas. Adjust only by authorized and 

licensed technicians. 

   

   

 

                   

Fig.5                                        Fig.6                                    Fig.7 

 

Summary of Contents for USFH-12-2

Page 1: ...Countertop Hot Plates Cooktops Operating Instructions Please read the following instructions carefully to ensure the best performance and safety while using this product Models USFH 12 2 USFH 24 4 USFH 36 6 ...

Page 2: ...ual for convenient reference and operation This instruction manual is subject to change without further notice and the manufacturer reserves the right of final interpretation The appliance is designed for commercial purposes not for household use A statement instructing the purchaser to post in a prominent location instructions to be followed in the event the user smells gas This information shall...

Page 3: ...ction 3 Brief Introduction 3 Manufacturer s Authority and Responsibility 3 Parameter Specifications 4 6 Transport and Storage 7 Installation and Debugging 7 9 Safety Notices and Precautions 10 Operating Instructions 11 12 Cleaning and Maintenance 13 14 Troubleshooting 15 Spare Parts 17 19 Accessories List 20 ...

Page 4: ...n our company production Which is quality designed reasonably structured conveniently operated durable and conveniently maintained Equipped with a cast iron burner high efficiency stainless steel tubular burner and pilot light to conveniently ignite the main fire burner This is hotel supermarket western restaurant and food industry s ideal cooking product equipment Manufacture s Authority and Resp...

Page 5: ... 4 Parameter Specifications Outline Dimensions in USFH 12 2 USFH 24 4 ...

Page 6: ... 5 USFH 36 6 ...

Page 7: ... of burners and control method Gas Species Intake tube pressure in W C Per BTU B T U h Total BTU B T U h Nozzle No USFH 12 2 2 pieces Independent control Natural Gas 4 25 000 50 000 43 L P Gas 10 25 000 50 000 53 USFH 24 4 4 pieces Independent control Natural Gas 4 25 000 100 000 43 L P Gas 10 25 000 100 000 53 USFH 36 6 6 pieces Independent control Natural Gas 4 25 000 150 000 43 L P Gas 10 25 00...

Page 8: ...n Code CSA B149 2 as applicable The appliance shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2psi 3 45kPa Unpacking and Installation Please dispose of all packaging materials and residues after unpacking Check the equipment If it is damaged please keep packing materials and receipts signed by the carr...

Page 9: ...only be placed on an incombustible counter top and keep a distance of at least 6 inches 152mm to equipment s sides and back and keep a distance of at least 4 inches 102mm to the bottom Do not put anything around the equipment on the counter top and bottom in order to avoid combustion and air circulation Leave enough distance in front of the equipment to take apart the control panel All major parts...

Page 10: ...se you will need to adjust gas pressure regulating valve or contact gas supplier to bargain Unplug pressure gauge after you accomplish Pressure testing then install needle type pressure joint screw arbor Important must screw joint screw arbor to prevent gas escape Fig 1 Debugging It s very important to debug the new stove Through the comprehensive system test of equipment we can ensure function an...

Page 11: ...eration do not directly touch burners and cooking grates Turn off the equipment while repairing maintaining or cleaning If the equipment has any problems or equipment damage gas piping leaks igniter or valve damage or lose product accessories do not operate and call for service immediately The use of attachments not recommended or sold by the manufacturer may cause fire personal injury or even dea...

Page 12: ... Revolve the main fire control valve knob anticlockwise after lighting the pilot light the main fire burner is lighted by the pilot light The power of burner increases as revolving angel increases When knob reaches to burner is in the maximum power Fig 4 Fig 2 Fig 3 Fig 4 Make sure there is air circulation at the bottom of equipment Do not use fan or air conditioning blowing at the flame in order ...

Page 13: ...Reinstall burner the pilot light head cooking grates and control panel in proper order Caution Each main fire orifice of the burner has been installed before delivery normal use without adjustment but only switching gas Adjust only by authorized and licensed technicians When you converse the gas source exchange the corresponding pressure maintaining valve which installed on air intake See 2 in P17...

Page 14: ...ng Wait for the equipment to cool down after the unit has been turned off before you clean Cut off the gas source when not in use If the equipment is not used for a long time clean the surface by wiping it with a soft cloth and place it in a well ventilated area Comprehensively check the equipment at least once every year by authorized and licensed technicians The product is made of 90 metals and ...

Page 15: ...ff valves when not in use Wipe panel and control valve knob with mild detergent Daily Catch tray Pull out catch tray from front body until the equipment cools down Use a cloth with cleaning agent to wipe unit surface wipe up residue Reinstall after cleaning Warning If the catch tray is permitted to fill too high should be cleaned Per use ...

Page 16: ... The main fire nozzle occlusion 2 Dredge nozzle 3 Gas control valves have problems 3 Change gas control valves 4 The pilot light and the main fire s distance is too far 4 Adjust the distance of them 5 Flame is too low 5 Adjust the height of the pilot light Close gas and heard a sound of fire 1 Insufficient gas pressure in pipe 1 Contact the local gas supply dept 2 Not match nozzle aperture with ga...

Page 17: ... diameter 3 Not enough air to ignite 3 Increase damper opening degree 4 In the peak of using gas sources of gas float heavy 4 Turn down valves flow Turn it up after the peak The problems mentioned above are only for reference If any fault occurs please stop use and contact authorized technician to check and repair Be sure to turn off the power and gas supply before maintenance ...

Page 18: ...right to void warranty service Order replacement parts from authorized representatives and after sale service agency Provide the model number serial number and description when you order components 5 4 3 1 2 6 7 8 9 10 11 12 14 15 3 16 17 19 18 20 21 23 22 24 26 27 29 13 25 28 Fig 8 ...

Page 19: ... 12 2 USFH 24 4 USFH 36 6 4 3 01E 08 Kirsite knob 2 USFH 12 2 4 USFH 24 4 6 USFH 36 6 5 2 11E 10 Control panel 1 605 185 USFH 12 2 2 11E 10 905 185 USFH 24 4 2 11E 10 1205 185 USFH 36 6 6 2 12E 10 surround 1 310 640 203 USFH 12 2 2 12E 10 2 12E 10 610 640 203 USFH 24 4 910 640 203 USFH 36 6 7 3 01E 08 A18 stopcock 2 A18 318 USFH 12 2 4 USFH 24 4 6 USFH 36 6 8 3 01E 08 A18 NAT GAS nozzle NG43 2 USF...

Page 20: ...d 2 A73007 TiPφ4 7 USFH 12 2 4 USFH 24 4 6 USFH 36 6 14 3 01E 08 Needle type pressure joint 1 1 8 27NPT USFH 12 2 USFH 24 4 USFH 36 6 15 3 01E 08 Needle type pressure joint screw arbor 1 M5 23 USFH 12 2 USFH 24 4 USFH 36 6 16 3 02E 08 Damper cover 2 USFH 12 2 4 USFH 24 4 6 USFH 36 6 17 3 01E 08 Stainless steel cross recess head screw 2 M4 8 USFH 12 2 4 USFH 24 4 6 USFH 36 6 18 3 01E 08 Short eject...

Page 21: ...ng valve connects with air intake must be installed by authorized and licensed technicians to ensure interface tightness 2 Screw the hex nut Fig 9 before connect air intake ensure gas mark Fig 10 on the plastic core whether match with connected gas source if not then pull out the plastic core and change another head insert it again The same as exchanging gas source 3 When exchange gas source use t...

Page 22: ...ntenance charge Keeping some components and necessary maintenance can prolong the length of the product Contact the dealer for assistance In order to avoid confusion please follow the format in figure 8 and table 4 US INC 6890 DISTRIBUTION DRIVE BELTSVILLE MD 20705 USA ...