Step 3:
Release the lever to close shutter
Step 2:
Depress the ferrule on the cleaning
tape using same pressure as a writing
pen. Move the connector from left to
right.
When cleaning angled polished
connectors (APC), be sure to turn the
ferrule so that end face is making
contact.
Step 1:
Open the shutter by gripping the
lever. The shutter will open and a
new section of cleaning tape will be
available.
How to Clean Connectors
Step 6 :
Engage the lever two or three times to
verify the cleaning tape is moving
smoothly.
Step 3 :
Load the new cleaning tape onto the
winding reel. Secure it using a
bonding tape.
Step 5:
Re-hook the cover onto the right side of
the cassette housing.
Re-snap the tab on the left side of the
cover
Step 2 :
Pull the cleaning tape from the
winding reel
Step 4:
Reinsert the winding reel and cassette
reel.
Route the cleaning tape over the guide
rollers and wiping board.
Step 1:
Turn the screw with a coin or flat
head screw driver.
Remove the cassette reel and
winding reel.
How to Replace The Cassette Reel
Caution!
•
Only use OPTIPOP R refills manufactured by NTT-Advanced Technology. Failure to use NTT-Advanced Technology
manufactured replacement refills may void the warranty.
•
Do NOT reuse cleaning tape as this may cause cross contamination and cause permanent damage.
•
A new refill is needed when the lever becomes difficult to depress.
•
Do not leave the cassette in temperatures exceeding 60
˚
C/140
˚
F for extended periods.
•
OPTIPOP R cassettes are warranted for manufacturer and material defects only. Abusive, neglect or use for unintended
purposes are not covered not covered in the warranty.
For technical support or re-ordering information, please contact US Conec Ltd at:
+1.828.323.8883 (international) 1.800.769.0944 (US and Canada)