USB 9640 5-Channel LED PAR
© US Blaster Europe BV
Connection of DMX
Connect the provided DMX XLR cable to the female 3-pin XLR output of your controller and the
other side to the male 3-pin XLR input of the fixture (please refer to the figure “
Installation and
Operation
” below).
You must chain multiple fixtures together through serial linking, never split your DMX connections
unless you are using a splitter/signal amplifier.
DMX addressing
All fixtures should be given a DMX starting address when using a DMX controller, so the correct
fixture responds to the correct control signal. This digital starting address is the channel number
from which the fixture starts to "listen" to the digital control information sent out from the DMX
controller. The allocation of this starting DMX address is achieved by various combining the
dipswitches.
This fixture employs 10 dipswitches to access its functions. Normally the dipswitches from #1 to
#9 are used for encoding DMX address, the dipswitch #10 for enabling DMX mode.
Dipswitch 1 address equals to 1
Dipswitch 2 address equals to 2
Dipswitch 3 address equals to 4
Dipswitch 4 address equals to 8
Dipswitch 5 address equals to 16
Dipswitch 6 address equals to 32
Dipswitch 7 address equals to 64
Dipswitch 8 address equals to 128
Dipswitch 9 address equals to 256
DMX address=Dipswitch 1+Dipswitch 2+…+Dipswitch 9.