2. Downlink Payload Structure
A downlink message can be sent from gateway to sensor in order to perform some actions on
that device.
Note:
the application port of EM500-SWL is 85.
Downlink Packet Example
Frame N: Set the data reporting interval as 20mins (1200s).
ff 0b ff ff 01 01
Channel
Type
Value
Channel
Type
Value
ff=255
0b = 11
(Device Restart
Notification)
ff
(reserved)
ff=255
01 = 1
(Custom Format
Version)
01 = 1
(Version 1)
ff 16 61 26 a1 08 75 05 00 35
Channel
Type
Value
ff=255
16 = 22 (Device SN)
61 26 a1 08 75 05 00 35
ff 09 01 00 ff 0a 01 01
Channel
Type
value
Channel
Type
Value
ff = 255
09
(Hardware version)
0100
(V1.0)
ff = 255
0a
(Software Version)
0101
(V1.1)
ff 0f 00
Channel
Type
value
ff = 255
0f (Class Type)
00 (Class A)
1 Byte
2 Bytes
1 Byte
1 Byte
2 Bytes
1 Byte
Channel1
Data1
0xff (Reserved)
Channel2
Data2
0xff (Reserved)
ff 03 b0 04
Channel
Type
Value
ff = 255
03 (Set Reporting Interval)
b0 04 => 04 b0 = 1200 (second)
Summary of Contents for EM500-SWL
Page 1: ......