EM500-SWL User Guide
8
If the transmitter is to be used in a well or other locations with turbulence or other disturbances,
it is advisable to install a pipe to protect the transmitter. Several holes should be drilled at
different heights of the pipe in order to let water flow into and remove dydrodynamic pressure.
Note:
The pipe can’t be placed bend.
4.2 EM500 Installation
Ensure the location of EM500 is within the communication range of LoRaWAN gateway.
4.2.1 Wall Mounting
1. Attach the mounting bracket to the wall and drill. (Around 16mm)
Note:
The connecting line of two holes must be a horizontal line.
2. Mount the device on the wall.
4.2.2 Pole Mounting
1. Loosen the hose clamp by turning the locking mechanism counter-clockwise.
2. Straighten out the hose clamp and slide it through the rectangular holes in the mounting
Summary of Contents for EM500-SWL