OPERATION
• Make sure air pressure is set correctly at the
pump
CAUTION: Never point the control valve at an-
yone or at any part of the body. The gun dispenses
grease at very high pressures, possibly resulting in
skin injection.
• Never put your hand or fingers over the coupler.
• Never stop or deflect leaks with your hand, body,
glove or rag.
• Tighten all fluid connections before operating
the equipment.
• Do not alter or modify this equipment.
• When not in use, always turn off the air supply
to the grease pump.
GREASING A GREASE FITTING/GREASE NIPPLE:
The grease coupler provided at the end of the
control valve extension tube has a jaw type cons-
truction. The coupler jaws will snap on to a grease
fitting and maintain a tight fit. When connecting
the coupler to the grease fitting, press the coupler
straight onto the grease fitting to form a snug fit.
Start operating the control valve with the coupler
as inline to the grease fitting as possible. Once
greasing is completed, release the control handle,
slightly tilt the coupler, twist and pull back. The
tilt and twist action will allow easy removal of the
coupler from the grease fitting.
CAUTION: Note that this is a continuous flow
valve & will keep dispensing grease while the han-
dle is pressed. Be careful not to over lubricate!
MAINTENANCE
Grease Control Valve should be kept clean and
checked for damage before each use. Control
valve does not have any filters built in, it is there-
fore important that grease flowing into the valve
is clean.
Make sure grease pump has a filter at its inlet.
If due to any reason, the valve fails to function,
never open the valve. Return product to the place
of purchase for replacement if within one year of
date of purchase.
TROUBLESHOOTING
GREASE FLOWS WITHOUT PRESSING THE CON-
TROL HANDLE
Grub Screw on top of the valve has been over-
tightened, resulting in constant opening of the
valve. Loosen the grub screw by rotating it in the
counter-clockwise direction. Tighten the top Nut.
Damaged Ball inside the control valve. Send back
the unit for replacement with a new ball. Return
product to the place of purchase for replacement
if within the warranty period.
NO GREASE FLOW WHEN CONTROL HANDLE IS
PRESSED
Grub Screw on top of the valve may have beco-
me loose. Loosen the top nut & tighten the grub
screw by rotating it in the clockwise direction.
Valve may be blocked due to impurities in grease.
Remove the grease supply hose from valve inlet
and carefully clean the valve using compressed air.
GREASE LEAKING FROM TOP OF THE VALVE
Worn seal. Return product to the place of purcha-
se for replacement if within the warranty period.
TECHNICAL DATA
5
E N G L I S H •
User’s manual
INLET PRESSURE
MAX. OUTLET PRESSURE
6 000 PSI (413 BAR)
10 000 PSI (689 BAR)
INLET PRESSURE
MAX. OUTLET PRESSURE
6 000 PSI (413 BAR)
8 000 PSI (XXX BAR)
23615
23616
23615-23616 manual.indd 5
28/05/15 15:13