background image

11

DS1148-001

also set the second digit. At this point, the display 

will show:

‘tXY’

where ‘XY’ is the new door release time set. 

After  3  seconds,  the  display  will  return  to  normal 

functioning.

ADVANCED PROGRAMMING

FUNCTIONS

A  number  of  particular  functions,  not  generally 

used, are described below.

DELETION OF AVAILABLE KEYS

To delete an available user key from the memory, 

you can use a simpler procedure than that described 

above for lost keys:

− 

using a MASTER key, access the deletion menu 

with the following shown on the display:

− 

present the key to be deleted.

− 

if the key presented is effectively present in the 

memory, the buzzer will emit three beeps and the 

display will show the ‘key number’ for approx. 7 

seconds.

− 

when  the  key  number  is  shown  on  the  display, 

present the MASTER key to confirm deletion.

To restore normal functioning, present a MASTER 

key to the front panel.

ACCESS  IN  THE  CASE  OF  LOSS  OF 

MASTER  KEY/STORAGE  OF  NEW 

MASTER KEYS

It  is  always  possible  to  access  a  device,  even 

without  the  MASTER  keys,  provided  you  have  a 

blank key, i.e. a key that has never been stored as 

user key on that device.

Proceed as follows:

−  open  the  frame,  so  as  to  access  the  rear  red 

button.

− 

press the rear red button 

briefly

;

− 

wait until the following is displayed:

 

− 

press the rear red button again 

briefly

;

− 

present  the  blank  key  which  will  be  stored  as 

MASTER key in addition to or in replacement of 

(if  3  have  already  been  stored)  of  the  MASTER 

keys present.

− 

present  this  new  MASTER  key  for  at  least  7 

seconds so as to restore normal functioning.

− 

use this new MASTER key to access the device.

ACCESS PASSWORD

Access from the rear red button can be protected 

using a 3-digit password.

When a password is entered in the device, the rear 

red button can be accessed subsequently only re-

entering the password.

WARNING:

If  all  the  MASTER  keys  of  a  device  equipped 

with  password  are  lost  and  you  have  forgotten 

the  password,  IT  IS  IMPOSSIBLE  TO  ACCESS 

DEVICE  PROGRAMMING.  In  this  case,  get  in 

touch  with  the  URMET  technical  assistance 

service directly which will eliminate the password 

without deleting any of the user keys.

The  password  can  be  set  on  any  device  without 

password (therefore on any device that leaves the 

factory).

Once the password has been entered, it cannot be 

modified.

It can be deleted only using the complete memory 

reset  procedure  (see  below):  IT  IS  ADVISABLE 

THEREFORE  TO  ENTER  THE  PASSWORD 

BEFORE

 STARTING TO STORE THE USER KEYS 

SO  THAT  THIS  CAN  BE  DELETED  IN  THE  CASE 

OF ERRORS DURING THE ENTRY PHASE.

Proceed as follows:

− 

press the rear red key 

briefly

;

− 

wait until the following is displayed:

− 

press  the  rear  red  key  and  hold  it  down.  The 

following is displayed:

  and  the  ‘0’  digit  increases  by  one  unit, 

approximately  once  a  second,  cyclically  (i.e. 

moving from 9 to 0).

  Release the key when the digit you want to set is 

displayed.

  Press  and  release  the  rear  red  key  again  twice 

so as to set the other two digits. Now the display 

will  show  the  configured  password.  Press  the 

rear  red  key  briefly  to  confirm  the  password. 

In  this  way,  you  will  access  the  MASTER  key 

programming menu from which you can exit using 

a MASTER key as described in the ‘Installation 

and Configuration’ paragraph.

Summary of Contents for Sinthesi 1148/45

Page 1: ...SIMIT INTEGRATED DOOR RELEASE MODULE WITH PROXIMITY READER MODULE OUVRE PORTE INTEGRE AVEC LECTEUR DE PROXIMITE M DULO DE APERTURA DE LA PUERTA INTEGRADO CON LECTOR DE PROXIMIDAD T R FFNERMODUL MIT LE...

Page 2: ...legata collegando l alimentazione il pulsante di apriporta dell androne interno e l elettroserratura Prima di completare l installazione della pulsantiera eseguire la configurazione In fase installati...

Page 3: ...nte cancellazione di chiavi perse etc Presentare al frontale una chiave qualunque che si vuole trasformare in chiave MASTER una delle tre barrette si sposter dal basso all alto ad indicare l avvenuta...

Page 4: ...te smarrita INDISPENSABILE conoscere il numero della chiave smarrita Presentare la chiave MASTER e mantenerla appoggiata per almeno 2 secondi Sul display comparir e la cifra 0 si incrementer di una un...

Page 5: ...sponga di una chiave vergine cio mai memorizzata come chiave utente in quel dispositivo Occorre aprire il telaio della pulsantiera in modo da accedere al pulsante posteriore rosso premere brevemente i...

Page 6: ...e posteriore rosso e mantenendolo premuto rialimentare il dispositivo continuare a mantenere premuto il pulsante fino allo scomparire della scritta A questo punto il display inizier a contare alla rov...

Page 7: ...ione superiore a 999 il punto decimale destro indicher chiavi comprese tra 1000 e 1999 quello centrale chiavi comprese tra 2000 e 2999 Ad esempio chiave n 560 chiave n 1502 chiave n 2070 Codici di err...

Page 8: ...in the attached diagrams connecting the power supply the door opening button in the entrance and the electric lock Before completing the push button panel installation perform the configuration Durin...

Page 9: ...med for 3 minutes after accessing programming the device automatically returns to normal functioning 1 Power on the device and check that the following are displayed in sequence the indication display...

Page 10: ...is displayed the first digit of the number of the lost key Repeat the above operations with the MASTER key twice so as to set the other two digits At this point the display will show the number of th...

Page 11: ...econds so as to restore normal functioning use this new MASTER key to access the device ACCESS PASSWORD Access from the rear red button can be protected using a 3 digit password When a password is ent...

Page 12: ...a small screwdriver insert the memory device in the new module powered off paying particular attention to the direction of insertion as shown in the figure HOW TO STORE MORE THAN 500 USER KEYS In part...

Page 13: ...layed during programming are given below A key not produced by Urmet has been presented to the front panel Key memory full An attempt is being made to delete a key not present in the memory Key memory...

Page 14: ...l alimentation la touche d ouverture de porte du hall int rieur et la serrure lectrique Avant de terminer l installation de la plaque de rue effectuer la configuration Lors de l installation tenir co...

Page 15: ...ifications ajout de nouvelles cl s usager effacement de cl s perdues etc Pr senter une cl quelconque la fa ade pour la transformer en cl MASTER une des trois barrettes passera du bas en haut pour indi...

Page 16: ...CLEs USAGER Pour effacer une cl usager perdue il est INDISPENSABLE de conna tre le num ro de la cl perdue Pr senter la cl MASTER et la garder appuy e 2 secondes au moins L afficheur visualisera le chi...

Page 17: ...m moris e comme cl usager dans ce dispositif Il faut ouvrir le bo tier afin d acc der la touche arri re rouge appuyer bri vement sur la touche arri re rouge attendre l affichage de appuyer nouveau bri...

Page 18: ...tionnement normal REMPLACEMENT d un dispositif EN PANNE Si l on remplace un dispositif en panne pour viter de devoir reprogrammer les cl s usager il faut d placer la m moire cl s d un module l autre P...

Page 19: ...ra tre en phase de programmation ont la signification suivante On a approch de la fa ade une cl non produite par Urmet M moire cl s pleine La cl que l on essaie d effacer n est pas pr sente dans la m...

Page 20: ...i n el pulsador de apertura de la puerta del vest bulo interior y la cerradura el ctrica Antes de completar la instalaci n del teclado efectuar la configuraci n En fase de instalaci n conviene tener e...

Page 21: ...as llaves usuario para cancelar llaves perdidas etc Colocar ante a la parte delantera una llave cualquiera que se quiera transformar en llave MASTER una de las tres barras de mover de abajo hacia arri...

Page 22: ...memorizar Para volver al funcionamiento normal apoyar una llave MASTER en la parte delantera CANCELACI N sustituci n llaves usuario Para cancelar una llave usuario perdida es INDISPENSABLE conocer el...

Page 23: ...r 7 segundos aproximadamente el n mero de llave cuando el visualizador muestra el n mero de llave acercar la llave MASTER para confirmar la cancelaci n Para volver al funcionamiento normal acercar una...

Page 24: ...se describe en el punto Instalaci n y Configuraci n PUESTA A CERO total de la memoria Es posible cancelar completamente el contenido de la memoria por ej para utilizar otra vez el dispositivo en una...

Page 25: ...aci n al m dulo Cuando se encienda nuevamente el m dulo de apertura de la puerta reconocer autom ticamente la memoria de capacidad superior sin que hagan falta otras operaciones En este caso los punto...

Page 26: ...ersichtlich an die Stromversorgung die T r ffnertaste im Hausflur und den elektrischen T r ffner anschlie en VorderVervollst ndigungderInstallation des Tastenfelds die Konfiguration ausf hren Bei der...

Page 27: ...erungen z B Speichern neuer Benutzerschl ssel oder L schen verlorener Schl ssel gebraucht Vor die Frontplatte einen beliebigen Schl ssel halten der als MASTER Schl ssel definiert werden soll Einer der...

Page 28: ...ENUTZERSCHL SSELS Um einen verlorenen Benutzerschl ssel l schen zu k nnen MUSS dessen Nummer bekannt sein DerEinheiteinenMASTER Schl sself rmindestens 2 Sekunden zeigen Auf dem Display erscheint Die Z...

Page 29: ...eit zugreifen auch wenn kein MASTER Schl ssel vorhanden ist sofern ein neuen Schl ssel vorhanden ist d h einen der in dieser Einheit noch nie als Benutzerschl ssel gespeichert wurde Dazu mu man den Ra...

Page 30: ...splay das eingestellte Passwort Die rote Taste kurz dr cken um die Einstellung zu best tigen Es ffnet sich das Men zur Programmierung von MASTER Schl sseln das man wie in dem Abschnitt Installation be...

Page 31: ...n Beim Wiedereinschalten erkennt das Modul automatisch den neuen gr eren Speicher ohne da weitere Operationen n tig w ren In diesem Fall dienen die Dezimalpunkte dazu die Schl ssel mit Nummern ber 999...

Page 32: ...sformer Ref 9000 230 separately approved and short circuit protection must be used For DC power the product must be powered by an external power supply the output of which complies with the requiremen...

Page 33: ...azione in c c con comando di una serratura di sicurezza Solution with dc power supply with control of a safety lock Solution avec alimentation en c c avec commande d une serrure de s curit Soluci n co...

Page 34: ...lutions pr sent es sur les sch mas Variante para apertura de la cerradura el ctrica incluso mediante pulsador exterior o contacto de la llave de cartero de tipo mec nico habilitados por un timer con f...

Page 35: ...ntation Alimentador Netzger t Timer fasce orarie Time band timer Temporisateur plages horaires Timer con franjas horarias Zeitschaltung Pulsante esterno o contatto chiave postino tipo meccanico Mechan...

Page 36: ...pr sente Urmet S p A d clare que les lecteurs de proximit R f 1158 45 et R f 1148 45 sont conformes aux exigences essentielles et aux autres dispositions pertinentes de la Directive 1999 5 CE L origin...