urmet domus K-STEEL 1072/14 Manual Download Page 6

−−−− 

sec.2b

K-STEEL CALL MODULE

BIBUS 2

nd

 Ed. VOP - Technical Manual

Ref. 

072/

4

K-STEEL CALLING MODULE WITH REPERT

ORY

6.  Fasten the module holder frame to the flush mounting boxes by 

means of the specific hinged attachment.

7.  Fit the seal and close the frame.

K-STEEL CALLING MODULE WITH REPERTORY Ref. 072/4

INSTALLATION

The holes in the upper part must only be used for introducing the 

cables if overlapped to other boxes.

2.   Flush the box and the required height considering the direction 

and the indications provided for video systems.

 

Warning

:  During  installation,  protect  all  parts  which  will  be 

exposed to view from mortar, plaster and cement.

 

Never use abrasive detergents to clean units.

3.   Fit  the  flush  mounting  box  in  line  with  the  wall:  it  must  not 

project. 

The wall surface on which the front rests must be as smooth as 

possible (max. tolerance 1.5 mm).

4.  If the internal production has been removed from the box for any 

reason, insert it as shown in the figure. Fix it in the upper part not 

used for fixing the module holder frame.

  

IMPORTANT

: the  warranty  conditions  will  be  forfeited  if  the 

protection is either not installed or installed incorrectly. 

5.  For fitting, loosen the two tap screws and remove the crossbar 

from the embedding box frame. Fit the modules in the frame.

§

§

max.

6 mm

n° 4 M4 x 16 mm

X

7

4

1

0

8

5

2

9

6

3

A

B

C

n° 7 M3

Summary of Contents for K-STEEL 1072/14

Page 1: ...NGS 3 OPERATION 3 Calls to users 3 Direct call to concierge switchboard 4 Door opener codes 4 Busy function 4 adjustments 5 Volume adjustment 5 Display contrast regulation 5 ADDITIONAL ALPHABETIC KEYB...

Page 2: ...ischarge and hold current with programmable activation time from 1 to 30s Programmable door phone pick up time 10 20 30 40s Programmable minimum guaranteed conversation time 10 20 30 40s Maximum conve...

Page 3: ...tion SE2 Electrical lock connection MP2 terminal board L1 Bus line 1st wire L2 Bus line 2nd wire GND Reference electrical ground PA Hall door opener button input SP Open door sensor contact input MV1...

Page 4: ...g a call The following message indicates busy status The keyboard is disabled during this time Two cases can occur BUSY TIME BEFORE THE CALL USER GOES ON HOOK This is the maximum time for the user to...

Page 5: ...ERNEATH or by THE SIDE OF the calling module INSTALLATION Calling module with repertory Ref 1072 14 can be used alone or in combination with a camera unit and or alphabet keyboard add on Ref 1038 73 E...

Page 6: ...tect all parts which will be exposed to view from mortar plaster and cement Never use abrasive detergents to clean units 3 Fit the flush mounting box in line with the wall it must not project The wall...

Page 7: ...d with module holder frame The available models and the dimensions of cases and frames are shown in Technical product manual door phone and video door phone systems section Modular Vandal proof panel...

Page 8: ...1072 14 Ref 1755 30A Ref 1755 30A Ref 1755 30A Ref 1755 30A Ref 1038 73 Ref 1038 73 Ref 1155 62 Ref 1155 61 Ref 1072 14 Ref 1155 62 S N Ref 1072 14 Ref 1072 14 Ref 1038 73 Ref 1038 73 Ref 1155 61 S N...

Reviews: