urmet domus K-STEEL 1072/14 Manual Download Page 3

sec.2b 

−−−− 

3

K-STEEL CALL MODULE

BIBUS 2

nd

 Ed. VOP - Technical Manual

Ref. 

072/

4

K-STEEL CALLING MODULE WITH REPERT

ORY

To restore default settings:

Disconnect module power.

Hold  the  red  programming  button  pressed  and  power  up  the 

module.

Hold  the  button  pressed  for  approximately  10  seconds  and  wait 

for a tone.

Release the button.

OPERATION

CALLS TO USERS

A  user  can  be  called  by  entering  the  user’s  code  on  the  keypad. 

Obviously, the code must be known to do so. The name can be sought 

in the integrated electronic directory if the code is not known.

CALLS TO USERS BY SELECTING THE NAME

The following message will appear on the display:

Press   or   to scroll the names and the codes. Hold either button 

pressed to increase scrolling speed.

Select the name and press 

 to call the selected user.

The apartment door phone will ring for approximately 3 seconds. Hold  

 pressed to send up to three consecutive calls.

Name/code display example:

The following prompt will appear on the display if 

 is not pressed for 

longer than two seconds after selecting a name:

At this point, press 

 to call or press   or   to scroll the name list.

The  following  will  appear  on  the  display  when  the  button 

  is 

pressed:

Press   to interrupt the call to the previously selected user.

The following message will appear on the display if the user picks up 

the handset:

Press   to end the conversation with the user.

The following message will appear if the user does not answer within 

the programmed pick-up time:

DESCRIPTION 

OF 

TERMINALS 

AND 

CONNECTORS

MP terminal board

~0 

Power 12Vac

~12 

Power 12Vac

+T 

Back-up power positive

GND 

Back-up power negative

SE1 

Electrical lock connection

SE2 

Electrical lock connection

MP2 terminal board

L1 

Bus line 1st wire

L2 

Bus line 2nd wire

GND 

Reference electrical ground

PA 

Hall door opener button input

SP 

Open door sensor contact input

Mv terminal board

SN 

Video power unit on signal for video door phone systems 

Video  switching  enable  signal  for  video  door  phone 

systems 

R1 

Video power ground 

MS terminal board

Door opener code time band contact input

Mail key input

GND 

Reference electrical ground

+EP 

Auxiliary device power

DT 

Not used

CNA 

Alphabetic keyboard connector 1038/73

CNP 

Programming keyboard connector 1032/65

CNS 

PC serial line connector

The module is programmed by default with a jumper between ground 

and the “SP” signal to simulate the door closed contact. Remove the 

jumper and connect the sensor between GND and SP when the open 

door contact is required.

Connect the electrical lock positive to terminal SE1 and the negative 

to terminal SE2 when polarised electrical locks are used.

IMPORTANT: Observe the instructions contained in section  for 

wiring and maximum distances.

TECHNICAL SPECIFICATIONS

Power: 

2vac rated

Stand-by consumption: 

300mAac max.

Maximum consumption: 

600mAac max. (*)

R signal: 

Imax=80mA

Lock hold current: 

90mA max.

Working temperature range: 

-0 +50°C

Humidity: 

90% RH at 30°C

(*)  With alphabetic keyboard 1038/73.

DEFAULT SETTINGS

Refer  to  section  1A  “Programming”  in  this  manual  for  how  to 

program the device.

The default settings of the device are:

System type:  

 

2nd Edition

Station type:  

 

main

Code format:  

 

numeric (000–9999)

Station number: 

 

Pick-up time:  

 

20s

Busy time:   

 

20s

Door opener time: 

 

pulse

§

K-STEEL CALLING MODULE WITH REPERTORY Ref. 072/4

DESCRIPTION OF TERMINALS AND CONNECTORS - TECHNICAL SPECIFICATIONS

DEFAULT SETTINGS - OPERATION 

Select NAME

with 

↑ 

or 

To call

press

 

URMET

1001

CALL

IN COURSE

TALK

PLEASE

User

does not reply

Summary of Contents for K-STEEL 1072/14

Page 1: ...NGS 3 OPERATION 3 Calls to users 3 Direct call to concierge switchboard 4 Door opener codes 4 Busy function 4 adjustments 5 Volume adjustment 5 Display contrast regulation 5 ADDITIONAL ALPHABETIC KEYB...

Page 2: ...ischarge and hold current with programmable activation time from 1 to 30s Programmable door phone pick up time 10 20 30 40s Programmable minimum guaranteed conversation time 10 20 30 40s Maximum conve...

Page 3: ...tion SE2 Electrical lock connection MP2 terminal board L1 Bus line 1st wire L2 Bus line 2nd wire GND Reference electrical ground PA Hall door opener button input SP Open door sensor contact input MV1...

Page 4: ...g a call The following message indicates busy status The keyboard is disabled during this time Two cases can occur BUSY TIME BEFORE THE CALL USER GOES ON HOOK This is the maximum time for the user to...

Page 5: ...ERNEATH or by THE SIDE OF the calling module INSTALLATION Calling module with repertory Ref 1072 14 can be used alone or in combination with a camera unit and or alphabet keyboard add on Ref 1038 73 E...

Page 6: ...tect all parts which will be exposed to view from mortar plaster and cement Never use abrasive detergents to clean units 3 Fit the flush mounting box in line with the wall it must not project The wall...

Page 7: ...d with module holder frame The available models and the dimensions of cases and frames are shown in Technical product manual door phone and video door phone systems section Modular Vandal proof panel...

Page 8: ...1072 14 Ref 1755 30A Ref 1755 30A Ref 1755 30A Ref 1755 30A Ref 1038 73 Ref 1038 73 Ref 1155 62 Ref 1155 61 Ref 1072 14 Ref 1155 62 S N Ref 1072 14 Ref 1072 14 Ref 1038 73 Ref 1038 73 Ref 1155 61 S N...

Reviews: