2 VOICE - Technical Manual

PUSH BUTTON PANEL

ASSOCIATION OF DOOR UNITS BUTTONS TO 

USERS

In two-family systems with double call station, one station can be 

associated with user 0 and the other with user 1:

Con

fi

 gure the two call stations as “single-family” (AUX dip 6 = 

OFF).

Con

fi

 gure the call station associated with user 0 as main (AUX dip 

1 = OFF) and ID = 0.

Con

fi

 gure the call station associated with user 1 as secondary (AUX 

dip 1 = ON) with address 1 (AUX dip 2 = ON) and ID = 0.

Position the rotary switch (CONV TIME) of the call station associated 

with user 1 to position “9”. The station emits a con

fi

 rmation tone.

On the call station associated with user 1, set the number of the 

door speaker unit ID = 1.

Change the position of AUX dip switch no. 5 (the call module emits 

a con

fi

 rmation tone).

Set again the AUX dip switch no. 5 in its previous position (the call 

module emits a con

fi

 rmation tone).

Set again the ID dip switches in their previous position (ID = 0).

Exit from advanced con

fi

 guration, returning the rotary switch to the 

position for setting guaranteed conversation time.

TC

column

interface

TC

CODE = 1

INT = 0

Z = ON

Z = OFF

INT = 0

CODE = 0

User 1

User 0

Call

station "B"

Call

station "A"

AUX 5 = ON

AUX 6 = OFF

CODE 2÷6 = 0

CONV TIME = pos 3

DOOR TIME = pos 0

AUX 5 = ON

AUX 3 = OFF

AUX 4 = ON

AUX 2 = OFF

AUX 1 = OFF

ID = 0

ID = 0

AUX 1 = ON

AUX 2 = ON

AUX 4 = ON

AUX 3 = OFF

AUX 6 = OFF

DOOR TIME = pos 0
CONV TIME = pos 3

LINE

LINE

IN0

IN1

LI

N

E

1

POWER

LINE1

power supply

The main call station “A” calls only user 0 with both keys while the 

secondary call station “B” calls only user 1 with both keys.

On the call module “B”:

Access to advanced con

fi

 guration;

Set the ID dip switch to 1;

Move the AUX dip switch no. 5;

Set again all the dip switches in their previous position;

Exit from the advanced con

fi

 guration.

PROGRAMMING DATA DELETING

To delete all the data programmed in the advanced con

fi

 guration, 

follow the instructions below:

Go to advanced con

fi

 guration (CONV TIME = 9).

Holding down any key for at least 5 sec., the door speaker unit 

emits a warning tone to con

fi

 rm cancellation.

MIKRA PUSH BUTTON PANEL

ASSOCIATION OF DOOR UNITS BUTTONS TO USERS - PROGRAMMING DATA DELETING

MIKRA PUSH BUTTON PANEL

Summary of Contents for 2 VOICE exigo

Page 1: ...atures 2 Structure 2 Terminal pins description 2 Technical characteristics 2 Default programming 3 Operation 3 Audio adjustment 3 INSTALLATION 4 Wall mounting 4 Flush mounting 5 MIKRA EXIGO PUSH BUTTO...

Page 2: ...rmed with dip switch Off hook waiting time 60 seconds system busy The guaranteed communication time can be programmed with rotary switch up to 70 seconds system busy Max conversation time starting whe...

Page 3: ...VATION Door units are provided with two terminal pins for pedestrian electric lock activation SE SE The electric lock is activated in the following cases Each time the entrance hall button is pressed...

Page 4: ...panel of the push button panel Install the push button panel at the height shown 1 55 1 60 m Connect the wires and set the dip switches Fit the name tag on the extractable front panel Close the push...

Page 5: ...1 60 m Fix the push button panel base to the frame provided with the flush mounting box CLICK Put the frame with the base in the flush mounting box and make cables come out of the hole The connection...

Page 6: ...on panel to the frame Screw the frame to the push button panel base Self tapping screws 2 9 x 9 5 mm Screw the frame with the push button panel to the flush mounting box Self tapping screws 2 9 x 16 m...

Page 7: ...o levels Execute the programming Fix the push button panel to the front panel CLICK Press the back of the push button panel to ensure perfect alignment of the camera CLICK Screw the front panel to the...

Page 8: ...g the door opening button on the calling station when an audio conversation has been established or when after having received a call or auto on function either a video connection has been established...

Page 9: ...uration returning the rotary switch to the position for setting guaranteed conversation time TC column interface TC CODE 1 INT 0 Z ON Z OFF INT 0 CODE 0 User 1 User 0 Call station B Call station A AUX...

Page 10: ...10 sec 3c 2 VOICE Technical Manual PUSH BUTTON PANEL...

Reviews: