![urmet domus 1784/45 Installation And Use Booklet Download Page 25](http://html1.mh-extra.com/html/urmet-domus/1784-45/1784-45_installation-and-use-booklet_1062535025.webp)
25
DS1784-005
Key memory absent or faulty
Key memory data consistency error.
Write to memory error.
6. MAINTENANCE
Use a soft damp cloth to clean the front panels. Do not use products containing alcohol or window cleaning
products.
7. TECHNICAL SPECIFICATIONS
Power voltage: ...............................................................................................
12 V~ 24 V~ or 10.5 V 24 V
Consumption (max): .......................................................................................................
250 mArms @ 12 V
~
200 mArms @ 24 V
~
Operating temperature: .............................................................................................................
-10 °C + 55 °C
Door open contact:
Type of contact:...........................................................................................................................
C, NC, NO
Max. switchable voltage: .......................................................................................................................
30 V
Max. switchable current: ......................................................................................................................
3,5 A
Max.
load:
................................................................................................................................
40 VA / 25 W
Timing:
.............................................................................................................................................
0 ÷ 99 s
Supported user key type: .....................
Dual technology key (Ref. 1125/52) or Mifare Plus (Ref. 1125/53)
or Mifare (Ref. 1125/54)
Max. number of keys that can be stored ....................................
2000
(1997 user keys and 3 master keys)
Dimensions (WxHxD): ..........................................................................................................
99 x 120 x 30 mm
Wires with cross-section area of 0.5 mm
2
or larger must comply with IEC 60332-1-2; wires with
crosssection area smaller than 0.5 mm
2
must comply with IEC 60332-2-2.
8. KEY TO SYMBOLS
Symbol
Description
Direct input voltage
~
Alternating input voltage
See the installation manual of the device
9. SIMPLIFIED EU DECLARATION OF CONFORMITY
Hereby, URMET S.p.A. declares that the radio equipment types:
ILA MODULE AND PROXIMITY KEY READER FOR MIKRA
with code
Ref. 1784/45
is in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the following internet address:
www.urmet.com