19
DS1784-001
3.3.5 Default
settings
All default door unit settings are:
Function
Default
Corresponding DIP switch
Station type
Main (OFF)
SW4
DIP switch 1
Secondary calling station address
0 (OFF)
SW4
DIP switch 2
Door opener
Private (OFF)
SW4
DIP switch
3
Interruption
Not enabled (OFF)
SW4
DIP switch
4
Camera LED on
Function ON
SW4
DIP switch
5
Number of users
One-family (OFF) 1784/1
Two-family (ON) 1784/2
SW4
DIP switch
6
Door unit number (ID)
0 (all OFF)
SW3
DIP switch
1 ÷ 5
Door opening time
1 sec (OFF - OFF)
SW2
DIP switch
1 - 2
Auto-on restriction with even ID code
Function OFF
SW2
DIP switch
3
Call address button management
0 (OFF)
SW2
DIP switch
4
DOOR STATUS or LETTERBOX function
Door status (OFF)
SW2
DIP switch
5
50/60 Hz camera
50 Hz (OFF)
SW2
DIP switch
6
Guaranteed communication time rotary
30 seconds (pos 3)
SW1 Rotary switch
Default con
fi
guration Ref. 1784/1
SW2
SW3
SW4
SW1
Default con
fi
guration Ref. 1784/2
SW2
SW3
SW4
SW1
3.3.6 Speaker
volume
adjustment
Volumes are calibrated by default so not to require adjustments in most cases.
Use a screwdriver to adjust the speaker volume, if required